Search
Displaying 431 to 440 of 526 items.
… issue 1/98, the operator noted that the attach point and firewall moved when force was applied. Further … reported cases, the stabilizer pulley bracket was cracked and the rivets were sheared. These rivets attach the bracket and nose gear mount fitting. This failure weakens the gear …
3
… AL 2006-04 18 September 2006 Overhaul of Flap Actuators Operators of Bombardier … exhibited high wear rates. It was determined that some overhaul facilities may have been identifying the actuator as … for backlash until 3000 hours in service following the « Overhaul ». If the ball screw and nut assembly have not been …
11.24
… Canada is issuing this SDA to ensure that operators and maintainers are aware of, and are following the latest Instructions for Continued … which includes Inspection Requirements Manual PSM 1-6-7 and Service Bulletin 6/523 - Special Inspection of Control …
5.887
… PW150A engine prompted an operator to conduct unscheduled Hot Section Inspections on the rest of their engines. The … and P&WC has investigated the original occurrence engine. Hot section distress was noted in several areas. A review of … … Engine Hot Section Deterioration and Engine Condition Trend …
23