Part VI - General Operating and Flight Rules

Canadian Aviation Regulations (CARs) 2019-1

Standard 621 - Obstruction Marking and Lighting

Amendment Foreword
(effective 2016/03/01)

1. PURPOSE. The purpose of this publication is to provide standards for marking and lighting of objects that present a hazard to the safe operation of aircraft.

2. EFFECTIVE DATE. The requirements of this edition are effective 30 days after the date of publication.

3. CANCELLATION. Standard 621, Obstruction Marking and Lighting, 1st Edition, dated 31 December 2011 is cancelled by this publication.

4. STANDARDS CHANGES AND EXISTING FACILITIES. Unless otherwise directed by the Minister, existing installations of marking and/or lighting do not need to be upgraded if installed prior to the effective date of this 2nd edition, with the exception of installations as indicated in section 601.26 of the Canadian Aviation Regulations (CARs) for which there is an external change [e.g. removal of a shielding object or air traffic pattern].

5. APPLICATION. In accordance with section 601.24 of the CARs, persons having responsibility for or control over a building or object that constitutes an obstacle to air navigation shall either mark and light the building, structure or object in accordance with the requirements of Standard 621, or use equivalent marking and lighting approved by the Minister.

6. EXPLANATION OF CHANGES

  • Old section 1.2. Moved to Chapter 2, section 2.5.
  • New section 1.2. Abbreviations added.
  • Section 2.1. Purpose of Marking and Lighting Requirements. Added information notes and tables to explain lighting criteria and aircraft acquisition distance. This gives the rationale for light intensities.
  • Paragraph 2.2(5)(a). Removed "objects such as a bridge", since the subject is catenaries. Shielding by bridges will be subject to a Ministerial evaluation.
  • Paragraph 2.2(5)(b). Separation distance is changed to 300 m from 600 m so as to be consistent with the observation distance for catenary wire markers.
  • Figure 2-2. Added note for markers on one counterpoise.
  • Subsection 2.3(1). Added reference to ISO/IEC Guide 17025.
  • Section 2.4. Removed "as defined by the applicable zoning law" since the use of high intensity lighting may not be in the zoning law, but the proponent should still check with the authority having local jurisdiction.
  • New subsection 2.5(3). For catenaries and other objects over navigable waterways, the proponent should contact the local Navigation Protection Program (NPP) office.
  • New subsection 2.5(4). The previous recommendation is raised to a standard.
  • New section 2.6. Correction of Lighting Failure. Allows non-notification of failure for steady burning lights.
  • New section 2.7. Light Failure Notification added. This expands upon subsection 4.7(7) in the previous edition.
  • New section 2.8. Object Height Tolerance. To accommodate installation that may have FAA tower height levels. This provides a transition from imperial to metric dimensions.
  • Section 4.1. Removal of "marking requirements of catenary wires, catenary support structures, moored balloons and kites, for daytime" which are addressed in the pertinent chapters.
  • Table 4-2. Added alternative red for reduction of bird fatalities.
  • Subsection 4.2(3). Information Note 2. Added exception for rotating CL-865 regarding installation at heights less than 60 m.
  • Subsection 4.2(5). Information Note. Removed, since the issue is addressed elsewhere.
  • Section 4.3. Floodlighting. Deleted because the visibility of the objects is dependent upon the angle of light projection and the reflectivity of the object. The proponent can still propose floodlighting as an equivalent, however this would be subject to specific evaluation.
  • Section 4.7. Monitoring of Obstruction Lights. Significantly revised to put the onus of responsibility to "know" on the proponent. Various methods are identified. Inspection is obviated if the method includes self-diagnosis. Figure 4-2 is added as information.
  • Section 5.1. Added Information Note.
  • Subsection 5.2(2). Moved in sequence to follow the format of FAA AC 70/7460-1.
  • New paragraph 5.3(2)(e). Statement that beacons are on the outside of the tower. This resolves the issue obscuring of lights placed interior to the tower.
  • Figure 5-2. Revised to follow paragraph 5.3(2)(e).
  • New section 5.4. Alternative Configuration A to reduce bird fatalities. To allow reduction of lights to minimize bird fatalities. This adopts the FAA practice.
  • Section 5.5 Chimneys, Flare Stacks and Similar Solid Structures. Revised for clarity.
  • Section 5.8 Groups of Objects. Revised for clarity.
  • New section 5.10. Ice Shields. To address the application of ice shields to prevent damage to lights.
  • Section 6.1. New Information Note to make a distinction between medium intensity flashing lights of the strobe-type and rotating-type.
  • New section 6.2. Application. To require synchronous flashing of medium intensity lights.
  • Section 6.4. New Information Note concerning lighting of appurtenances.
  • Subsection 6.4 (4). Removed paragraph (c), since this is a recommendation.
  • Figure 6-1. Revised to reference subsection 6.4(4).
  • New subsection 6.4(5). Requirements for omitting paint for heights under 150 m.
  • Subsection 6.4(6). Requirement for painting for heights over 150 m.
  • New section 6.7. Prominent Buildings and Similar Extensive Obstructions. Adopts FAA practice.
  • Figure 7-4. High intensity lighting ends at 150 m. This reflects established practice.
  • Subsection 7.5(2). New Information Notes to interpret requirements for lighting appurtenances.
  • Subsection 7.7(4). Requirements for objects exceeding 60 m for both dimensions.
  • New subsection 8.2(3). For combined CL-865 and CL-864 lights.
  • Section 8.3. New Information Note concerning control.
  • Section 10.3. Markers. Revised to separately address structure markers and shore markers.
  • New paragraph 10.4(1)(e). Provides criteria [1000 m distance] for assessment of wire markers of shapes other than spherical.
  • New paragraph 10.4(1)(f). Provides criteria for markers near runway ends.
  • Subsection 10.6(2). New information note on the use of lighting. Example is that of an installation in Hong Kong.
  • Section 10.7. Lighting of Catenary Support Structures. Introduces 5 configurations of lighting.
  • New Figure 10-4. Lighting configurations for catenaries.
  • Subsection 10.7(2). Allows use of lighting place of marking as for other skeletal structures.
  • Section 10.8. Lighting with use of Aircraft Detection System (ADS). Revised to stress the need for assessment and approval by the Minister.
  • New section 10.9. Site Maintenance / Clearance. Added to emphasize clearing of obscuring vegetation.
  • Chapter 11 - Marking and Lighting of Tethered Objects. Chapter renamed to give pertinence to tethered objects.
  • New subsection 11.1(2). Identification of winched gliders as not part of this chapter for reason that the exposed tether is not permanent.
  • New section 11.3. Tethered objects more than 150 m AGL. New section for tethered objects more than 150 m in height. This is to address tethered generators and wind sails that are more than 150 m AGL.
  • Figure 12-1. Revised to show inner dominant wind turbine.
  • Paragraph 12.2(1)(a). Paint required only for top 2/3 of the support mast. This reflects established practice.
  • New paragraph. 12.2(1)(b). Paint required for lattice-work support masts.
  • Subsection 12.2(1). Added orange colour to the Information Note.
  • Subsection 12.2(2). Emphasis added for twilight and night protection.
  • Subparagraph 12.2(2)(b)(iii). Lighting may be necessary for more than one wind turbine.
  • Section 12.3. Wind turbines of Total Height Exceeding 150 m. Revised to provide requirements for wind turbines of more than 150 m by adopting international practice.
  • New Figure 12-2. Illustration of lighting required to 315 m.
  • New section 12.5. Temporary Lighting During Construction. Adopts FAA practice for temporary lighting.
  • New section 12.6. MET Towers (meteorological towers). Adopts FAA practice for marking MET towers.
  • Revision of Table 13-1. Clarifies the photocell settings. Settings in footcandles are given to match actual units for supplied photocells.
  • New Table 13-2. Control Settings. Provided to put the lighting control in one location.
  • New Table 13-3. Characteristics of obstacle lights. Adopts ICAO practice whilst maintaining FAA practice for, such as, CL-856 and CL-857.
  • New Table 13-4. Minimum Intensity and light distribution for low-intensity obstacle lights (Figure 13-1). Continues Transport Canada practice for CL-810 which follows ICAO practice for low intensity type B, albeit the beam is +2.5 to +12.5 degrees.
  • New Table 13-5a. Minimum Effective intensities of flashing lights (a) (Figure 13-2). Adopts ICAO practice that the minimum intensities are standards.
  • New Table 13-5b. Recommended maximum effective intensities of flashing lights (a)(d) (Figure 13-2). Adopts ICAO practice that the maximum intensities are recommendations.
  • Table 13-5(f). Provides specification for the intensity of the red beam.
  • New Figures 13-1 and 13-2. Illustrate the photometric requirements for low, medium and high intensity obstacle lights.
  • New subsection 14.2(2). Provides inspection frequency for powerline markers.
  • Section 15.1. Scope. The use of the word "radar" is replaced with "sensor" in order to avoid prescriptive terminology. This change is applied throughout Chapter 15.
  • Section 15.2. Impact Boundary. Revises horizontal distance from the object as 30 m to 60 m.
  • Subsection 15.3(2), Table 15-1. The time before impact is changed from 20 seconds to 30 seconds.
  • Paragraph 15.3(5)(a). Makes the provision of an audio signal optional for all but catenary crossings.
  • Subsection 15.3(6). Warning Zones. Information Note revised for clarity.

LIST OF FIGURES

  • Figure 2-1: Adjacent Structures
  • Figure 2-2: Shielding of Cable Spans
  • Figure 3-1: Day Marking - Checkerboard Pattern
  • Figure 3-2: Day Marking - Banded Pattern
  • Figure 3-3: Storage Tank Marking
  • Figure 4-1: Configurations of Lighting on Skeletal Structures
  • Figure 4-2: Methods of Monitoring
  • Figure 5-1: Configuration A: Red Lighting Installation
  • Figure 5-2: CL-810 and CL-864 Lights on Towers
  • Figure 5-3: Alternative Configuration A - Lighting Reduction to Reduce Bird Fatalities
  • Figure 5-4: Prominent Buildings Lighting
  • Figure 5-5: Bridge Lighting
  • Figure 5-6: Groups of Objects
  • Figure 6-1: Configuration "D": Medium Intensity White Flashing Lighting System;
  • Figure 7-1: Adjacent Building
  • Figure 7-2: Lighting Adjacent Structures
  • Figure 7-3: Lighting Adjacent Structures
  • Figure 7-4: Configuration "B" and "C": High Intensity White Flashing System
  • Figure 7-5: Hyperbolic Cooling Tower
  • Figure 10-1: Catenary Markers
  • Figure 10-2: Catenary Wire Lights
  • Figure 10-3: Catenary Flashing Lights
  • Figure 10-4: Catenary Configurations
  • Figure 10-5: Catenary Flashing Lights with ADS
  • Figure 12-1: Lighting Wind turbines; Heights up to 150 m AGL
  • Figure 12-2: Lighting Wind turbines; Heights 150 m to 315 m
  • Figure 12-3: MET Tower Marking
  • Figure 13-1: Photocell Settings
  • Figure 13-2: Low Intensity Photometric Requirement
  • Figure 13-3: High and Medium Intensity Flashing Photometric Requirement
  • Figure 14-1: In-service Aviation Orange Colour Tolerance Chart
  • Figure 15-1: Catenary Crossing - Plan View
  • Figure 15-2: Catenary Crossing - Profile View
  • Figure 15-3: Potential Turning/Descent Manoeuvres

CHAPTER 1   INTRODUCTION

1.1 Definitions 

In this Standard:

"appurtenance" - (Note: this term is defined as "projection" in the CARs) means that part of any vertical mast, pole or other appendage added to a building, structure or object that protrudes above the top of the building, structure or object; (accessoire)

"aviation colours" - for lighting, the colours as defined in the ICAO Annex 14; (couleurs)

"beam spread" - means the angle between the two directions in the vertical or horizontal plane in which the intensity is equal to 50 percent of the minimum specified peak beam effective intensity; (angle d’ouverture du faisceau)

"catenary" - means the curved span of overhead wires hung freely between two supporting structures, normally with regard to exceptionally long elevated spans over canyons, rivers and deep valleys; (caténaire)

"effective intensity" - means the effective intensity of a flashing light is equal to the intensity of a steady-burning (fixed) light of the same colour which produces the same visual range under identical conditions of observation; (intensité efficace).

"fixed light" - means a light having constant luminous intensity when observed from a fixed point; (feu fixe)

"lighting" - means any light displayed on an obstruction as a means of indicating the presence of the obstruction to pilots; (éclairage)

"lighting terms" - refer Figure 1-1 (unités photométriques)

  1. (a) Lumen - International System unit of luminous flux equal to the amount of light given out through a solid angle of 1 steradian by a point source of 1 candela intensity radiating uniformly in all directions. The unit expresses the quantity of light output per second. (lumen)

  2. (b) Candela - International System unit of luminous intensity of light emitted from a light source; equal to 1/60 of the luminous intensity per square centimetre of a blackbody radiating at the temperature of solidification of platinum (2,046° degrees Kelvin). A luminous intensity of one candela is one lumen per steradian (solid angle). The unit expresses the intensity of light within an incremental segment of the beam. (candela)
    (effective 2016/03/01)

  3. (c) Lux - International System unit of illumination, equal to one lumen per square metre (lm/m2). The unit expresses the amount of light falling on the surface area. (lux)

"marker" - means an object displayed on an obstruction during daytime as a means of indicating the presence of relatively invisible obstructions such as power lines; (balise)

"marking" - means a symbol, group of symbols, or markers that are displayed on the surface of an obstruction and intended to reduce hazards to aircraft by indicating the presence of the obstruction by day; (balisage)

"meteorological visibility" - means the greatest distance, expressed in statute miles, that selected objects (visibility markers) or lights of moderate intensity at night (25 candela) can be seen and identified under specific conditions of observation; (visibilité météorologique)

"painting" - means a marking applied to the surface of an obstruction and intended to identify the presence of the obstruction by day; (marque de peinture)

"vertical aiming angle" - means the angle formed between the horizontal and a line through the centre of the vertical beam spread. (calage en site)

"wind turbine" means a structure intended for the production of electrical power; comprising a support mast on which is installed a nacelle containing a generator unit and which supports rotor blades that are caused to rotate by the wind. The total height of the obstruction is the height of the nacelle, above ground level (AGL), plus the length of one of the blades held in a vertical position.(éolienne)

"wind farm" means a grouping of 3 or more wind turbines. (parc d’éoliennes)

"wind farm indicators" means light units installed with specified spacing on selected wind turbines and serving to indicate the location of a wind farm to pilots. (indicateurs de parc d’éoliennes)

1.2 Abbreviations and Symbols Used in this Standard
(effective 2016/03/01)

AGL

Above Ground Level

cd

candela (light intensity)

km/h

kilometres per hour

m

metre

kt

knot

FAA

Federal Aviation Administration

cm

centimetre

ft

foot

ICAO

International Civil Aviation Organization

max

maximum

min

minimum

ADS

Aircraft Detection System

FIC

Flight Information Centre

< x

less than x

> x

more than x

= x

equal to or more than x

= x

equal to or less than x

CHAPTER 2   GENERAL

2.1 Purpose of Marking and Lighting Requirements

Information Note 1:  The application of the marking and lighting requirements specified in this Standard and the approval of equivalent requirements is to ensure that an obstruction to air navigation remains visible at a range sufficient to permit a pilot in VMC conditions to take appropriate action in order to avoid the obstruction, by not less than 300 m vertically within a horizontal radius of 600 m from the obstruction. The purpose of obstruction marking and lighting standards is to provide an effective means of indicating the presence of objects likely to present a hazard to aviation safety. Equivalent lighting and marking requirements may be approved depending on terrain features, weather patterns, geographic location, and in the case of wind turbines, depending on the number of structures and overall layout of design.
(effective 2016/03/01)

Information Note 2:  Guyed Structures. The guys of a 610 m [2000 foot] skeletal tower are anchored from 490 m (1600 feet) to 610 m (2000 feet) from the base of the structure. This places a portion of the guys 460 m (1500 feet) from the tower at a height of between 38m (125 feet) to 150 m (500 feet) AGL. It is expected that pilots, when operating over other than congested areas, remain at least 150 m (500 feet) from manmade structures. Therefore, the tower must be cleared by 150 + 460 = 610 m (2000 feet) horizontally to avoid all guy wires. Properly maintained marking and lighting are important for increased conspicuity since the guys of a structure are difficult to see until aircraft are dangerously close.
(effective 2016/03/01)

Information Note 3:  Intensity Requirements. An aircraft travelling at 250 knots (463 km/hr) requires 1.48 statute miles (2.4 km) to avoid an object horizontally by 610m (2000 feet) once the pilot sees the obstruction light, recognizes the light as marking an obstruction, initiates evasive action and allowing for aircraft lag. An aircraft travelling at 165 knots (306 km/hr) requires 1.18 statute miles (1.9 km) to avoid an obstruction by 610 m horizontally. The lighting in Standard 621 provides the acquisition distances: for the 250 knot aircraft ... 32 cd nominal intensity in 3 statute mile (4.8 km) visibility; and for the 165 knot aircraft ... 2000 cd nominal intensity in 1 statute mile (1.6 km) visibility.
(effective 2016/03/01)

Table 2-1: Intensity and Acquisition Distance
(effective 2016/03/01)

Time period

Meteorological visibility
Statute miles (kilometres)

Distance
Statute miles
(kilometres) Footnote *

Nominal Intensity
(candelas)

Obstruction Light

 

 

0.64 (1.0)

32

CL-810

Night

1 (1.6)

1.18 (1.9)

2000

CL-864

 

 

1.5 (2.4)

20,000

CL-865

 

 

1.4 (2.3)

32

CL-810

Night

3 (4.8)

3.1 (5.0)

2000

CL-864

 

 

4.2 (6.8)

20,000

CL-864

 

 

1.5 (2.4)

200,000

CL-856

Day

1 (1.6)

1.35 (2.2)

100,000

CL-857

 

 

1.0 (1.6km)

20,000

CL-865

 

 

3.1 (5.0)

200,000

CL-856

Day

3 (4.8)

2.65 (4.3)

100,000

CL-857

 

 

1.8 (2.9km)

20,000

CL-865

 

 

Day to Night

 

 

Twilight

1 (1.6)

1.0 (1.6km) to 1.5 (2.4km) Footnote **

20,000

CL-865

 

3 (4.8)

1.8 (2.9km) to 4.2 (6.7km) Footnote **

20,000

CL-865

Information Note 4:  Conclusion. Aircraft travelling at 165 knots (306 km/hr) or less should be able to see the obstruction lighting in sufficient time to avoid the structure by at least 610m horizontally under all conditions of operation, provided the pilot is operating in accordance with the Canadian Aviation Regulations (CARs). Aircraft travelling between 165 knots (306 km/hr) and 250 knots (463km/hr) should be able to see the obstruction lighting unless the weather deteriorates to 1 statute mile (1.6 km) visibility at night during which time period 20,000cd would be required to see the lights at 1.5 statute miles (2.4 km). This intensity of 20,000cd if operated in 3 statute mile (4.8 km) visibility could generate a residential annoyance factor. In addition, aircraft in these speed ranges can normally be expected to operate under instrument flight rules (IFR) at night when the visibility is 1 statute mile (1.6 km).
(effective 2016/03/01)

2.2 Shielding

(1) The principle of shielding is applied in a way that a dominant permanent building, structure or object which is marked or lighted, or both, obviates the need for marking or lighting other buildings, structures or objects in the immediate surrounding area, which might otherwise be treated as individual obstructions.

(2) More specifically, the principle of shielding is applied if the marking or lighting, or both, of a dominant permanent building, structure or object is assessed by the Transport Canada regional office as providing sufficient warning to aircraft that, in avoiding the dominant obstruction, they will also avoid the unmarked or unlighted obstructions in the immediate surrounding area without risk of collision.

(3) Where two similar objects of equal height are situated adjacent to each other, as shown in Figure 2-1, one of the two objects may be considered as shielded, provided the separations listed in Table 2-1 are not exceeded.
(effective 2016/03/01)

Table 2-2:  Separation between Shielded Objects
(effective 2016/03/01)

Height of Objects AGL (metres) Maximum Separation (metres)

30 < x = 75

15

75 < x = 120

23

120 < x = 200

30

200 < x = 290

45

290 < x

60

(4) A narrow obstruction may be considered as shielded when it is situated with respect to a large obstruction so that an aircraft, whose flight path would avoid the large obstruction would, as a result, also avoid the narrow one.

Figure 2-1: Adjacent Structures
(effective 2016/03/01)

(5) Adjacent Catenaries

(a) A catenary across a recognized VFR route does not require marking or lighting where it is shielded by a higher catenary.
(effective 2016/03/01)

(b) A catenary segment may be considered as shielded when it is situated within 300 m of the marked catenary of the dominant obstruction so that it remains below a sloping down surface at a gradient of 5% projected from the marked catenary as shown in Figure 2-2.
(effective 2016/03/01)

(c) If the second catenary is above the gradient, this span may not be considered as shielded and is marked or lighted, or both, in accordance with this Standard.

Figure 2-2: Shielding of Cable Spans
(effective 2016/03/01)

(6) Complex Objects

(a) Where it is not possible to apply a uniform standard to a cluster of objects such as industrial plants, oil refineries, thermal generating stations, and similar structures, they shall be assessed by the Transport Canada regional office on an individual basis to determine whether or not to treat them as hazards to aviation safety or as an extended obstruction, taking into account the objects' location and height.

(b) When treated as an extended obstruction, sufficient marking or lighting, or both, are provided to ensure that the extent of the cluster is defined and visual warning is provided from any angle of aircraft approach.

2.3 Lighting Equipment

(1) Conformance

Information Note:  As a basis of ensuring procurement of equipment meets the requirements of this Standard, the person having responsibility or control over the obstruction should obtain an attestation of conformance through an established 3rd Party testing laboratory meeting ISO/IEC Guide 17025, "General Requirements for the Competence of Testing and Testing Laboratories."
(effective 2016/03/01).

(2) Combined Light Units

Information Note:  The requirements specified in this Standard are written with respect to the performance of obstruction lighting, without consideration of how they are actually designed. Manufacturers may supply light sources contained within a single fitting. For example, a combined CL-864 red flashing beacon with a CL-865 white flashing light, as may be used for a dual medium intensity, configuration "E" installation.

2.4 Environmental Evaluation

Information Note:  The person having responsibility or control over an obstruction may be required to file an environmental evaluation with the appropriate authority having jurisdiction when seeking authorization for the use of the high intensity flashing white lighting system on structures located in residential neighbourhoods.
(effective 2016/03/01)

2.5 Notification Responsibilities
(effective 2016/03/01)

(1) A person planning to erect or modify an obstruction, namely a building, structure or object, including a moored balloon or kite, either permanently or temporarily, contact the appropriate regional Transport Canada Civil Aviation office, as specified in Appendix A , at least 90 days prior to erection and provide the information on the planned obstruction, using the Aeronautical assessment form for obstruction marking and lighting as shown in Appendix C.
(effective 2016/03/01)

(2) If it appears that planned construction might create an obstruction to air navigation in the vicinity of a Department of National Defence (DND) aerodrome, the person having responsibility or control over the construction advise the appropriate DND authorities.

Information Note: Aerial cables over navigable waters: Persons planning to construct and/or place a work, including an aerial cable and any structures supporting the cable, should consider the requirements under the Navigation Protection Act (NPA). Under the NPA, all proposed works (including aerial cables) in, on, over, through, across, or under navigable waters listed in the NPA Schedule, may be subject to review and authorization by Transport Canada (TC) Navigation Protection Program (NPP) officials. Therefore, proponents of proposed works over scheduled waters need to contact their local TC NPP office for more information on the process for the review and authorization. It should be noted that the NPA also includes a Minor Works Order. Should the proposed work in a scheduled waterway meet the criteria listed in the Order, the work may proceed without authorization under the Act.

(3) Any person planning to erect an object also provides information to NAVCANADA, using the "Land Use Proposal Submission Form" (« Projet d'utilisation particulière d'un terrain ») which is available from the appropriate Transport Canada regional office. (See Appendix A)

Information Note:  Where possible, for objects such as broadcast antennae and wind farms, a sign identifying the owner of the object and providing contact information should be installed at the entrance gate or any other place as appropriate.

2.6 Correction of Lighting Failure
(effective 2016/03/01)

Conspicuity of the obstacle is achieved only when all required marking and lighting is working. Partial equipment failures decrease the margin of safety. Any outage is corrected as soon as possible. Failure of a steady burning side or intermediate light is corrected as soon as possible, but notification is not required.

2.7 Light Failure Notification
(effective 2016/03/01)

Failure or malfunction of lighting is reported immediately to the appropriate Flight Information Centre (FIC) so that a NOTAM can be issued. Failure of a steady burning CL-810 light is corrected as soon as possible, but notification is not required. Toll-free numbers for FICs are listed in Appendix A. The report should contain the following information:

  1. (a) name of persons or organizations reporting the light failure including any title, address, and telephone number;

  2. (b) the type of structure;

  3. (c) location of structure (including latitude and longitude, if known, prominent structures, landmarks, etc.);

  4. (d) height of structure above ground level (AGL)/above mean sea level (AMSL), if known;

  5. (e) an estimated return to service date.

Information Note 1: When the primary lamp in a double CL-810 obstruction light fails, and the secondary lamp comes on, no report is required. However, when one of the lamps in the incandescent CL-864 flashing red beacon fails, it should be reported, as both lamps must be operating to provide the required photometrics.

Information Note 2: The sponsor is responsible for calling the nearest FIC to extend the outage date duration or to report a return to service date.

2.8 Object Height Tolerance
(effective 2016/03/01)

Object height values contained in this Standard have a tolerance of [0, + 2%].

Information Note: The purpose of the tolerance is to enable a transition from FAA height criteria.

CHAPTER 3   MARKING AND MARKERS,
GENERAL
(effective 2016/03/01)

3.1 Scope

Chapter 3 governs marking requirements for obstructions to air navigation in order to make them conspicuous to pilots during daylight.

3.2 Paint Standards

Where alternate sections of aviation orange and white, referred herein as "orange" and "white" paint markings, are required under this Standard to be displayed on a building, structure or object, the colours of paint markings shall be in accordance with United States Federal Standard FED-STD-595B, for colours identified as:

  1. (a) orange, number 12197; and

  2. (b) white, number 17875.

3.3 Surfaces Not Requiring Paint

(1) Except as otherwise provided for in Chapter 3, ladders, decks, and walkways of steel towers and similar structures are not to be painted, if a painted surface presents a potential hazard to maintenance personnel.

(2) Subject to subsection (3), paint may be omitted from precision or critical surfaces, if it would have an adverse effect on the transmission or radiation characteristics of a signal.

(3) Where markings are omitted under subsection (1) or (2), the overall marking effect of the structure shall not be reduced to the point of compromising the visibility criteria of section 2.1.

3.4 Use of Plastic Wrapping

In the case of poles, where the use of paint is impractical, a wrapping of plastic or other weather resistant material, in the required colours and dimensions, may be applied instead of painting provided that the colour of the wrapping corresponds as close as possible to that required for a painted marking.

3.5 Paint Patterns

Information Note:  The following patterns of painting are dependent upon the size and shape of the structure.

(1) Solid Pattern

A structure is coloured solid orange, if the structure has both horizontal and vertical dimensions not exceeding 3.2 m.

(2) Checkerboard Pattern

(a) Subject to paragraph (c), alternating rectangles of aviation orange and white are displayed on the following types of structure

  1. (i) storage tanks for water, gas, grain, and similar tanks,

  2. (ii) buildings,

  3. (iii) structures that both:

    1. (A) appear broad from a side view, that are 3.2 m or more across horizontally, and

    2. (B) have a horizontal dimension that is equal to or greater than the vertical dimension.

(b) Checkerboard patterns have the following characteristics [refer to Figure 3-1]:

  1. (i) for structures having horizontal and vertical dimensions, both greater than 3.2 m, the sides of the checkerboard pattern measure not less than 1.5 m nor more than 6 m,

  2. (ii) for structures having horizontal or vertical dimensions, both less than 4.5 m, the sides of the checkerboard pattern may be less than 1.5 m, but not less than 1 m,

  3. (iii) the rectangles of the pattern are as nearly square as possible, and

  4. (iv) corners are coloured orange.

(c) The following exceptions apply to the marking requirements set out in this subsection:

  1. (i) storage tanks not suitable for a checkerboard pattern are coloured with alternating bands of aviation orange and white or a limited checkerboard pattern applied to the upper one-third of the structure, and

  2. (ii) the skeletal framework of certain water, gas, and grain storage tanks may be excluded, as a result of a risk evaluation, from the checkerboard pattern, where the main structure of the storage tank is large enough that its checkerboard pattern adequately suits the purpose of day marking.

Figure 3-1: Day Marking - Checkerboard Pattern
(effective 2016/03/01)

(3) Colour Bands

(a) Subject to subsection (4), alternate bands of orange and white are displayed on the following types of structure:

  1. (i) communications towers and supporting structures of overhead transmission lines,

  2. (ii) poles,

  3. (iii) chimneys,

  4. (iv) skeletal framework of storage tanks and similar structures,

  5. (v) wind turbine towers and rotor blades, including the nacelle or generator housing,

  6. (vi) cables, conduits, and materials attached to the face of a tower, whether at time of construction or when later added to the structure, and

  7. (vii) structures that appear narrow from a side view, that are 3.2 m or more across horizontally, and the horizontal dimension is less than the vertical dimension.

(b) Bands applied to structures of any height in excess of 3.2 m [Refer to Figure 3-2]:
(effective 2016/03/01)

  1. (i) are approximately equal in width and to a tolerance of ± 10 percent,

  2. (ii) are not more than 30 m wide,

  3. (iii) are coloured orange for the top and bottom bands,

  4. (iv) have an odd number of bands on the structure, and

  5. (v) are in accordance with Table 3-1, except that for each additional 60 m or fraction thereof, one (1) additional orange and one (1) additional white band are added.

Table 3-1:  Structure Height to Number of Bands Requirement

 

Structure height (AGL)

 

Greater than
(metres)
Not exceeding
(metres)
Number of Bands

0

3.2

solid

3.2

210

7

210

270

9

270

330

11

330

390

13

390

450

15

450

510

17

510

570

19

570

630

21

Figure 3-2: Day Marking - Banded Pattern
(effective 2016/03/01)

(4) Structures With a Cover or Roof

If a structure referred to in subsection (3) has a cover or roof whose profile in the line of sight of approaching aircraft is less than 1.5 m, the highest orange band is continued to cover the entire top of the structure. It is acceptable to have the roof made of a solid orange provided that the structure below has a checkerboard pattern.

(5) Skeletal Structures Atop Buildings

Where a flagpole, skeletal structure, or similar object is erected on top of a building:

(a) the combined height of the object and the building determines whether marking is required; however, only the height of the object determines the width of the colour bands; and

(b) if the building is required to have a checkerboard pattern of marking, the object and its height are considered separately for banding determination.

(6) Appurtenances

If a tower or similar skeletal structure is required to have banded marking and it also has an appurtenance of more than 12 m, then the combined height of the appurtenance plus that of the main structure determine the width of the banding.

(7) Partial Marking 

If marking is required for only a portion of a structure because of shielding by other objects or terrain:

(a) the width of the bands is determined by the overall height of the structure;

(b) a minimum of three bands are displayed on the upper portion of the structure; and

(c) in the case of cylindrical storage tanks as shown in Figure 3-2, the checkerboard marking may be applied to the top ½ to 2/3 of the tank.

(8) Teardrop Pattern

Spherical water storage tanks with a single circular standpipe support may be marked in a teardrop-striped pattern having the following characteristics:

(a) alternate stripes of aviation orange and white are displayed on the tank, as shown in Figure 3-3;
(effective 2016/03/01)

(b) the stripes extend from the top centre of the tank to its supporting standpipe; and

(c) the width of the stripes is nearly as equal as possible and the width at the greatest girth of the tank is not to be less than 1.5 m nor more than 6 m.
(effective 2016/03/01)

Figure 3-3: Storage Tank Marking
(effective 2016/03/01)

(9) Community Names

If it is desirable to paint the name of the community on the side of a tank, the marking pattern may be broken for a height of not more than 1.0 m to serve this purpose.

3.6 Flag Markers

(1) Application

One or several flags may be used as markers instead of paint to indicate the presence of certain structures or objects when it is technically impractical to use spherical markers or painting.

Information Note:  Some examples of structures or objects where flags may be used are temporary construction equipment, cranes, derricks, oil and other drilling rigs.

(2) Characteristics

Flags used as markers under subsection (1) have the following characteristics:

(a) Minimum Size - each side of a flag is at least 0.6 m in length;

(b) Colour Patterns - they are coloured as follows:

  1. (i) if solid, the colour is orange,

  2. (ii) if orange and white colours are used, two triangular sections, one aviation orange and the other white, are arranged to form a rectangle, or

  3. (iii) a checkerboard pattern of aviation orange and white squares of 0.3 m to a side, is used if the flags are 0.9 m or larger;

(c) Shape - they are rectangular in shape and have stiffeners to keep it from drooping in calm wind; and

(d) Manner of Display - they are displayed as follows:

  1. (i) around, on top, or along the highest edge of the obstruction,

  2. (ii) when used to mark extensive or closely grouped obstructions, the flags are displayed approximately 15 m apart, and

  3. (iii) the flag stakes are to be of such strength and height that they are able to support the flags above all surrounding ground, structures, or objects of natural growth, as the case may be.

3.7 Omission of Marking with Use of Lighting

A high or medium intensity white flashing lighting system may be used in place of marking if the following conditions are met:

(a) the lighting system is operated 24 hours a day; and

(b) in the case of a medium intensity lighting system, the system:

  1. (i) is operated 24 hours per day, and
  2. (ii) the structure on which it is used is 150 m AGL or less.

CHAPTER 4   LIGHTING, GENERAL

4.1 Scope

Chapter 4 governs lighting requirements for obstructions to air navigation in order to make them conspicuous to pilots during night time, except as otherwise provided for in this Standard.
(effective 2016/03/01)

Information Note:  Lighting is used to warn pilots of a potential collision during night time operations. If the lighting is of sufficient intensity, it may also serve to give warning during daytime operations and may be approved, by way of a risk evaluation, in lieu of other means of day marking. Criteria for lighting structures, as a result of a risk evaluation, can vary depending on terrain features, weather patterns, and geographic location.

4.2 Lighting Systems

(1) Configurations

Obstruction lighting is displayed on a building, structure or object in one of six configurations, as shown in Figure 4-1 and listed in Table 4-2.

Information Note:  The following is a listing of light units required under this Standard. Chapter 13 provides detailed characteristics of these light units. Appendix B contains the governing electrotechnical requirements and quality assurance testing.

Table 4-1: Light Units

Type Intensity Colour Signal Flash Rate (fpm)

CL-810

Low

red

fixed

n/a

CL-864

Medium

red

flashing

20-40

CL-865

Medium

white

flashing

40

CL-866, Catenary

Medium

white

flashing

60

CL-885, Catenary

Medium

red

flashing

60

CL-856

High

white

flashing

40

CL-857, Catenary

High

white

flashing

60

Note 1:  In certain cases, some of these lights are supplied as a combined unit (e.g. CL-864/CL-865)

Note 2:  fpm = flashes per minute

Information Note:  The listing above for "catenary" applies to lighting of the support structures. Catenary wire lights meet the photometric requirements for CL-810.
(effective 2016/03/01)

Table 4-2:  Lighting Configurations
(effective 2016/03/01)

Configuration Lighting

A

CL-810 low and CL-864 medium intensity red lighting system

A'

Alternative red, light reduction to reduce bird fatalities

B

CL-856 white high intensity (without appurtenance lighting)

C

CL-856 white high intensity (with CL-865 appurtenance lighting)

D

CL-865 white medium intensity

E

Dual CL-810/CL-864 red with CL-865 white medium intensity lighting

F

Dual CL-810/CL-864 red with CL-856 white high intensity lighting

Figure 4-1: Configurations of Lighting on Skeletal Structures
(effective 2016/03/01)

(2) Red Lighting Systems

A red obstruction lighting system consists of CL-810 low intensity steady burning aviation red lights and CL-864 medium intensity red flashing aviation beacons.

(3) CL-865 Medium Intensity White Flashing Lighting Systems

(a) A medium intensity white flashing lighting system consists of CL-865 medium intensity flashing white lights used during day/twilight with automatically selected reduced intensity for night time operation.

(b) When the system is used on a building, structure or object 150 m AGL or less in height, the marking requirements may be omitted.

Information Note 1:  No exemption applies from the requirement to display markings on a building, structure or object exceeding 150 m AGL that has a CL-865 medium intensity white flashing lighting system.

Information Note 2:  This lighting system, except for the rotating type CL-865, is not normally recommended on buildings, structures or objects 60 m AGL or less.
(effective 2016/03/01)

(4) High Intensity White Flashing Lighting Systems

(a) A high intensity white flashing lighting system consists of CL-856 and CL-857 high intensity flashing white lights used during daytime with automatically selected reduced intensities for twilight and night time operations.

(b) When the system is in use, the markings and the other lights required to be displayed on the building, structure or object may be omitted.

Information Note:  This lighting system should not be used on buildings, structures or objects 150 m AGL or less, unless a risk evaluation shows otherwise.

(5) Dual Lighting Installation

(a) A dual lighting system consists of red lights for night time use and high or medium intensity flashing white lights for daytime and twilight use.

(b) When a dual lighting system incorporates medium flashing intensity lights on a building, structure or object 150 m or less in height, or high intensity flashing white lights on a building, structure or object of any height, the marking and the other lighting requirements may be omitted.

4.3 Obstruction Lights During Construction

  1. (1) As the height of a building, structure or object under construction progressively exceeds each level at which permanent obstruction lights would be required, two or more temporary medium intensity white flashing lights are installed at that level.

  2. (2) Temporary lighting required under subsection (1) is operated 24 hours a day until all permanent lights required under this Standard are in operation.

  3. (3) If practical, permanent obstruction lighting required under this Standard shall be installed and operated at each level as construction progresses.

  4. (4) The lights shall be positioned to ensure that a pilot has an unobstructed view from any angle of approach of at least one light at each level.

4.4 Temporary Construction Equipment Lighting

Information Note: Since there is such a variance in construction cranes, derricks, oil and other drilling rigs, each case should be assessed individually. However, in principle, lights should be installed according to the standards given herein, as they would apply to permanent structures.

4.5 Groups of Obstructions

(1) When individual buildings, structures or objects within a group of obstructions are not the same height and are spaced more than 45 m apart, the prominent building, structure or object within the group is lighted in accordance with the standards for individual obstructions of a corresponding height.

(2) If an outer building or structure is shorter than the prominent one, it is lighted in accordance with the requirements for individual obstructions of a corresponding height.

(3) Light units required under this section are placed to ensure that the light is visible to a pilot approaching from any direction.

(4) In addition to the requirement set out in subsection (3), at least one flashing beacon is installed at the top of a prominent centre obstruction or on a special tower located near the centre of the group.

(5) If there is no prominent centre obstruction, a risk evaluation shall be performed to assess the location of the applicable beacons.

4.6 Glare from Flashing Obstruction Lights

(1) Where obstruction lighting is likely to distract operators of aircraft, railway trains, surface vessels, and other vehicles, or if the lighting is in a congested residential area, a suitable shield is installed on the appropriate lights to minimize the glare effects of the light.

(2) The application of such shielding shall not diminish the required performance of the light as specified in Chapter 13 of this Standard for obstruction identification to pilots.

(3) Shielding applied to the exterior of the light unit is suitable for environmental conditions such as snow, ice and frost cover, so that the light output is not degraded from that required by this Standard.

(4) In the proximity of navigable waterways or along coastal regions, the installation of an obstruction lighting system is coordinated with marine authorities by the owner or operator of the obstruction in order to avoid interference with marine navigation.

4.7 Monitoring of Obstruction Lights

The objective of monitoring is to enable the owner to maintain the lighting system in operation without failure. The occurrence of light failure is detected so that a NOTAM can be issued and repair action undertaken in a timely fashion.
(effective 2016/03/01)

(1) The owner of a structure with a flashing obstruction light system is responsible:
(effective 2016/03/01)

(a) to know there is occurrence of any failure, by observation once every 24 hours, either visually or through observation of a remote indicator designed to show failure of such lighting regardless of position or colour. For medium and high intensity lighting and dual lighting systems, observation is made for at least the day and night modes of operation;

(b) to have a documented program of at least annual inspection of all automatic or mechanical control devices, indicators, and alarm systems associated with the structure lighting to ensure that the such apparatus is functioning properly.

(2) Is exempt from paragraph 4.7(1)(b) where the alarm system has self-diagnostic features to confirm the communication link and operational status of the monitoring system itself at least once every 24 hours.
(effective 2016/03/01)

(3) Where it is not possible to do observation either visually or through means of a remote indicator, the objective of monitoring is accomplished through provision of lamps having a rated life of more than one year of operation and establishment of a documented program of at least annual inspection.
(effective 2016/03/01)

(4) For each structure, a log is maintained showing the history of observations, inspections, failures, repairs, and relamping, as applicable for the method of monitoring used.
(effective 2016/03/01)

(5) The owner of the structure advises NAV CANADA, as soon as possible, of any obstruction light failure so that a NOTAM can be initiated in accordance with paragraph 2.7(1).
(effective 2016/03/01)

Information Note: Each flashing light system, in accordance with Appendix B, is to have a controller which gives indication of the status of both the flashing lights and any associated steady burning lights. The controller has provision to permit connection to a remote alarm indicator (supplied by others or as an option)
(effective 2016/03/01)

Figure 4-2 illustrates a variety of methods for monitoring. Method (a) is the use of an alarm system for failure indication only. Method (b) determines the status of all the lights in a 24 hour period, which may be considered as a form of self-diagnosis.

Since it is the responsibility of the owner to know of a failure, Method (b) may be chosen over Method (a) in consideration of reliability. If the failure alarm is given only at the time of occurrence, will the communication link and overall monitoring system be functioning properly to transmit the alarm to the owner?

Method (c) is an instance for which it is not possible to provide a communications link. For this method the objective of monitoring is accomplished through the use of lamps having a rated life of more than one year of operation combined with at least annual inspection and relamping. In the case of LED sources the owner may choose to not re-lamp based on experience; annual inspection, however, should still take place.

In the case of Method (d), monitoring would not normally be required as it is not a flashing light system. However, inspection and relamping should be undertaken as in Method (c).

Figure 4-2: Methods of Monitoring
(effective 2016/03/01)

4.8 Placement Factors

(1) The height of a building, structure or object above ground (AGL) is used to determine the number of light levels required to be installed as part of a lighting system.

(2) The height of light levels required to be installed may be adjusted slightly, but not to exceed 3 m, when necessary to accommodate guy wires and personnel who replace or repair light fixtures.

(3) Except for catenary support structures, the following factors are considered when determining the placement of obstruction lights on a building, structure or object:

(a) for a red obstruction lighting system or a medium intensity white flashing lighting system, the overall height of the structure including all appurtenances such as rods, antennae, obstruction lights and similar objects, determine the number of light levels;

(b) for a high intensity white flashing lighting system,

  1. (i) the overall height of the main structure excluding all appurtenances is used to determine the number of light levels, and
  2. (ii) if required, a CL-865 medium intensity flashing light is displayed on the highest portion of any antenna or other appurtenance supported by the main structure; and

(c) for a dual obstruction lighting system, the determination of the number of light levels is in conformity with the pertinent requirements for white and red lighting systems.

(4) The elevation of the tops of adjacent buildings or structures in congested areas is used as the equivalent of ground level to determine the proper number of light levels required.

(5) If an adjacent building, structure or object shields any light, horizontal placement of the lights is adjusted or additional lights are mounted on that object to retain or contribute to the definition of the obstruction.

4.9 Ice Protectors

(1) Where icing is likely to occur, metal grates or similar protective means are installed directly over each light unit required under this Standard to be installed on a building structure or object to prevent falling ice or accumulations from damaging the light units.

(2) The protective means are of a design and manner of placement such that the required photometric output of the fixtures is not affected.

CHAPTER 5   RED OBSTRUCTION LIGHTING SYSTEM, CONFIGURATION "A"

5.1 Scope

Chapter 5 governs obstruction lighting that uses a configuration "A" lighting system.

Information Note: Red Obstruction lights are used to increase conspicuity during nighttime. Daytime and twilight marking is required. Recommendations on lighting structures can vary depending on terrain features, weather patterns, geographic location, and in the case of wind turbines, number of structures and overall layout of design.
(effective 2016/03/01)

5.2 System Requirements

(1) General

(a) A configuration "A" red obstruction lighting system, as shown in Figure 5-1,consists of one or several CL-864 red flashing beacons or CL-810 steady burning red lights, or a combination thereof.
(effective 2016/03/01)

(b) When red lighting alone is used for night protection, no exemption to markings for day protection required under this Standard is allowed.
(effective 2016/03/01)

(c) Refer to Chapter 13 for control of red lighting systems.
(effective 2016/03/01)

Information Note: The CL-810 comes in two forms; a single unit [one lamp and one globe] and a double unit [two lamps and two globes].

(2) Single CL-810 Obstruction Light Units

Where more than one obstruction light is required either vertically or horizontally, or where maintenance can be accomplished within a reasonable period of time, single unit CL-810 lights may be used as follows:

(a) Top Level atop structures such as airport ILS buildings and long horizontal structures such as perimeter fences and building roof outlines; or

(b) Intermediate Level at intermediate levels on skeletal or solid structures when more than one level of lights is required to be installed and there are two or more single units per level.

(3) Double Obstruction Light Units

Subject to subsection (2), when used as a top light or in areas or locations where the failure of a single unit could cause an obstruction to be totally unlighted, double unit CL-810 lights are installed at each end of a row of single unit obstruction lights, and more specifically as follows:
(effective 2016/03/01)

(a) Top Level on a structure, building or object 45 m AGL or less, one or more double unit lights operating simultaneously are installed at the highest point;

(b) Intermediate levels,

  1. (i) double unit lights are installed when a malfunction of a single unit light could create an unsafe condition and in remote areas where maintenance cannot be performed within a reasonable time, and

  2. (ii) both lamps of the double unit operate simultaneously or a transfer relay is used to switch to the inactive lamp should the active lamp fail; and

(c) Lowest Level at the lowest level of a building, structure or object,

  1. (i) light units may be installed at a higher elevation than standard if the surrounding terrain, trees or any adjacent buildings would obscure the lights, or
  2. (ii) in certain exceptional instances, as determined by a risk evaluation, the lighting otherwise required for the lowest level may be omitted.

(4) Flashing Display

When one or more levels of lights are comprised of CL-864 flashing beacons, the lights flash simultaneously.
(effective 2016/03/01)

(5) Equivalent Method of Displaying Obstruction Lights

Provided that approval is obtained following the result of a risk evaluation, lights may be placed on poles equal to the height of the building, structure or object required to be lighted, and may be installed on or adjacent to such building, structure or object.

5.3 Poles, Radio and Television Towers and Similar Skeletal Structures
(effective 2016/03/01)

The following requirements apply to radio and television towers, supporting structures for overhead transmission lines, and similar structures. Refer to Figures 5-1 and 5-2.

(1) On the topmost part of a structure:

(a) 45 m AGL or less, two or more CL-810 steady burning lights are installed in a manner to ensure an unobstructed view of one or more lights by a pilot; or
(effective 2016/03/01)

(b) exceeding 45 m AGL, at least one CL-864 red flashing beacon is installed in a manner to ensure an unobstructed view of one or more lights by a pilot.
(effective 2016/03/01)

(2) On the intermediate levels of a structure:

(a) the number of levels of lights is in accordance with Figures 5-1;

(b) the number of lights at each level is determined by the shape and height of the structure;

(c) the lights are installed so as to provide an unobstructed view of at least one light by a pilot from any angle of approach;

(d) where CL-810 steady burning red lights are installed on:

  1. (i) a structure 105 m AGL or less, two or more steady burning red lights are installed on diagonally or diametrically opposite positions, and

  2. (ii) a triangular shaped structure 105 m AGL or less:

    1. (A) two red light units, single or double, are installed, provided that at least one can be viewed unobstructed by a pilot from any angle of approach, or

    2. (B) where the requirement specified in clause (A) is impractical, three red light units are installed, one on each apex of the triangular cross-section, or

  3. (iii) a structure exceeding 105 m AGL, a CL-810 steady burning red light is installed on each outside corner at each level; and
    (effective 2016/03/01)

(e) where CL-864 flashing red beacons are used on a structure exceeding 105 m AGL, the CL 864 lights at intermediate levels are installed on the outside of the tower structure on diagonally or diametrically opposite positions at each level.
(effective 2016/03/01)

Figure 5-1: Configuration A: Red Lighting Installation
(effective 2016/03/01)

Figure 5-2: CL-810 and CL-864 Lights on Towers
(effective 2016/03/01)

(3) Appurtenances

Where a building, structure or object required to be lighted includes an appurtenance such as a rod, antenna, or similar extension, a topmost light is installed above the main part of the building, structure or object in accordance with the provisions of this subsection.

(a) Where the appurtenance is 12 m or less in height and:

  1. (i) is incapable of supporting a red flashing beacon, the beacon may be placed at the base of the appurtenance, or

  2. (ii) if the mounting location does not allow unobstructed viewing of the beacon by a pilot from any angle of approach, additional beacons are added.

(b) Where the appurtenance exceeds 12 m in height and:

  1. (i) is incapable of supporting a red flashing beacon, a supporting mast with one or more beacons is installed adjacent to the appurtenance, and

  2. (ii) the adjacent installation of (i) does not exceed the height of the appurtenance and is within 12 m of the tip of the appurtenance to allow the pilot an unobstructed view of at least one beacon, from any angle of approach.

Information Note: The primary focus of "appurtenance" is to enable installation of a short rod, antenna or similar extension of less than 12 m in height without lighting. It is not intended that the feature of "appurtenance" would involve extensions that are significantly in excess of 12 m. In such an instance, the extension is to be considered as adding to the height of the main object.
(effective 2016/03/01)

5.4 Alternative Configuration A' to Reduce Bird Fatalities
(effective 2016/03/01)

(1) An alternative Configuration A' is applied for the purpose of reducing bird fatalities and consists of only CL-864 lights, as shown in Figure 5-3, for object heights of more than 105 m.
(effective 2016/03/01)

(2) For A1 heights of more than 45 m to 105 m, the CL-810 lights are made to flash at the same rate as the top mounted CL-864 light.
(effective 2016/03/01)

Information Note: The alternate Configuration A' is only applicable to towers and similar skeletal structures.
(effective 2016/03/01)

Figure 5-3: Alternative Configuration A - Lighting Reduction to Reduce Bird Fatalities
(effective 2016/03/01)

5.5 Chimneys, Flare Stacks and Similar Solid Structures

(1) Number of Light Units per Level

Subject to subsection (3), the number of lights to be installed at the top and at each level of a chimney, flare stack or similar solid structure depends on the diameter of the structure and is in accordance with Table 5-1.

Table 5-1:  Number of lights
(effective 2016/03/01)

Diameter Number of Lights at top and per level

= 6 m

3

6 m < x = 30 m

4

30 m < x = 60 m

6

x > 60 m

8

(2) Top Mounted Obstruction Lights
(effective 2016/03/01)

(a) For structures 45m AGL or less, CL-810 lights are installed horizontally at regular intervals at or near the top.

(b) For Structures Exceeding 45m AGL, at least three CL-864 beacons are installed.

(c) For chimneys, cooling towers, and flare stacks, lights may be displayed as low as 6 m below the top to avoid the obscuring effect of deposits and heat generally emitted by this type of structure.

(d) For flare stacks, as well as other structures associated with the petrol-chemical industry, depending upon assessment, normal lighting requirements may not be necessary. This could be due to the location of the flare stack/structure within a large well-lighted petrol-chemical plant or the fact that the flare, or working lights surrounding the flare stack/structure, is as conspicuous as obstruction lights.

Information Note: It is important that the lights be readily accessible for cleaning and lamp replacement.
(effective 2016/03/01)

(3) Mounting Intermediate Levels
(effective 2016/03/01)

(a) Steady Burning (CL-810) Lights. The number of light levels is obtained from Figure 5-1. At least three lights are installed on each level.

(b) Flashing (CL-864) Beacons. The number of beacon levels may be obtained from Figure 5-1. At least three lights are installed on each level, and

  1. (i) for structures 105 m AGL or less, intermediate levels of flashing lights are not required,

  2. (ii) for structures exceeding 350 feet (107 m) AGL at least three flashing (CL-864) beacons should be installed on each level in a manner to allow an unobstructed view of at least one beacon.

(4) Hyperbolic Cooling Towers

Where any cooling tower:
(effective 2016/03/01)

(a) is 180 m in height or less AGL, intermediate light levels may be omitted; or

(b) exceeds 180 m AGL in height, a second level of light units is installed approximately at the midpoint of the structure and in a vertical line with the top level of lights.

5.6 Prominent Buildings and Similar Extensive Obstructions

(1) Subject to subsection (4), individual obstructions having a similar height above ground and located not more than 45 m apart within a group of obstructions may be considered as an extensive obstruction for lighting purposes, in which case the group displays steady burning red lights to indicate the extent of the obstruction as specified in this section.

(2) On a structure 45 m or less in both horizontal dimensions:
(effective 2016/03/01)

(a) a CL-810 light is displayed on the highest point at each end of the major axis of the obstruction; or
(effective 2016/03/01)

(b) a dual CL-810 light is displayed in the centre of the highest point.
(effective 2016/03/01)

(3) On a structure exceeding 45 m in at least one horizontal dimension:
(effective 2016/03/01)

(a) CL-810 lights are displayed on:
(effective 2016/03/01)

  1. (i) the highest point at each end of the obstruction, and

  2. (ii) the highest points for each 45 m, or fraction thereof, for the overall length of the major axis.

(b) If the minor axis of a structure exceeding 45 m in one of its horizontal dimensions is 45 m or less in length, the lights referred to in paragraph (a) may be installed as a row along the middle or along either side, as shown in Figure 5-4.
(effective 2016/03/01)

(c) If a structure exceeding 45 m in any horizontal dimension is located near a landing area and two or more edges of the structure are of the same height, the edge nearest the landing area is lighted with CL-810 lights.

(4) Structures Exceeding 45 m AGL

(a) Top Lights - CL-810 steady burning red lights are installed on the highest point at each end.
(effective 2016/03/01)

(b) At intermediate levels of the structure,

  1. (i) CL-810 steady burning red lights are displayed for each 45 m or fraction thereof,
    (effective 2016/03/01)

  2. (ii) the vertical position of the intermediate lights is equidistant between the top lights and the ground level as the shape and type of obstruction will permit, and

  3. (iii) one CL-810 steady burning red light is displayed at each outside corner on each level with the remaining lights evenly spaced between the corner lights.

(5) Exceptions

Flashing red CL-864 beacons may be used instead of CL-810 steady burning lights if early or special warning to pilots is necessary, provided that, in the case of an extensive obstruction:
(effective 2016/03/01)

(a) they are displayed on the highest points of the obstruction, at intervals not exceeding 900 m; and

(b) at least three beacons are displayed on one side of the obstruction to indicate a line of lights.

Figure 5-4: Prominent Buildings Lighting
(effective 2016/03/01)

5.7 Bridges

(1) A bridge assessed through a risk evaluation as a likely hazard to aviation safety has CL-864 red flashing lighting, as shown in Figure 5-5.
(effective 2016/03/01)

(2) If the bridge referred to in subsection (1) is over navigable water, the obstruction lighting installer consults with the Coast Guard to avoid interference with signals to marine navigation.

Figure 5-5: Bridge Lighting
(effective 2016/03/01)

5.8 Groups of Objects

(1) When objects within a group of obstructions are approximately the same overall height AGL and are located not more than 45 m apart, the group of obstructions may be considered an extensive obstruction and lighted in accordance with section 5.6.
(effective 2016/03/01)

Information Note: Where the objects are not more than 45 m apart, the grouping effectively simulates a building for the pilot as shown in Figure 5-6. The lights are installed as shown in Figure 5-3 and some of the objects may be unlighted.
(effective 2016/03/01)

(2) Where individual objects, except wind turbines, within a group of closely spaced obstructions may or may not be of the same height and the spacing between individual structures is not in all cases equal to or less than 45 m apart:
(effective 2016/03/01)

(a) the prominent objects within the group are lighted in accordance with the standards for individual obstructions of a corresponding height;

(b) if the outer structure is shorter than the prominent, the outer structure is lighted in accordance with the standards for individual obstructions of a corresponding height; and

(c) at least one flashing beacon is installed at the top of a prominent centre obstruction or on a special tower located near the centre of the group.

Information Note: The emphasis is on "closely spaced" and for which the central beacon can serve for protection of the overall group. Because of the variation, the installation should be subject to assessment by Transport Canada Civil Aviation.
(effective 2016/03/01)

Figure 5-6: Groups of Objects
(effective 2016/03/01)

5.9 Characteristics of Lights

Lighting displayed on a bridge has the light characteristics specified in Chapter 13.

5.10 Ice Shields
(effective 2016/03/01)

Where icing is likely to occur and metal grates or similar protective ice shields are installed directly over each light unit to prevent falling ice or accumulations from damaging the light units, the lights are mounted in a manner to ensure an unobstructed view of at least one light by a pilot approaching from any direction.

CHAPTER 6   MEDIUM INTENSITY WHITE SYSTEM, CONFIGURATION "D"
(effective 2016/03/01)

6.1 Scope

Chapter 6 governs obstruction lighting that uses a configuration "D" lighting system.

Information Note: The CL-865 light can be of two forms: (1) a strobe type which produces a flash by means of an omnidirectional burst of light output, or (2) by means of rotation creating a beam of light which passes the pilot eye producing a flashing display.
(effective 2016/03/01)

6.2 Application

Use of CL-865 medium intensity white flashing light units:
(effective 2016/03/01)

(a) during daytime and twilight with automatically selected reduced intensity for night time operation;
(effective 2016/03/01)

(b) where used on a building, structure or object 150 m AGL or less in height, day marking otherwise required under Chapter 3 can be omitted; and
(effective 2016/03/01)

(c) are designed so that all lights on the tower flash synchronously.
(effective 2016/03/01)

Information Note: Strobe type CL-865 medium intensity white flashing light units should not be used:
(effective 2016/03/01)

(a) on a building, structure or object 60 m AGL or less in height;

(b) in urban areas due to their tendency to merge with background lighting making it difficult for some types of aviation operations; and
(effective 2016/03/01)

(c) in these areas at night and can be a cause of residential glare complaints; and
(effective 2016/03/01)

(d) on structures within 5 kilometres of an airport.

6.3 Characteristics

(1) Photometrics

The photometric output of a configuration "D" lighting system is in accordance with Table 13–2.

(2) Control

The lighting system is in accordance with Table 13-1 for day, twilight and night modes of operation.

6.4 Radio and Television Tower and Similar Skeletal Structures

(1) Subject to subsection (4), on a radio or television tower, or similar skeletal structure, the number of light levels to be installed depends on the height of the structure, including antennae and similar appurtenances, and is determined in accordance with Figure 6-1.

Information Note: The location of the topmost light [as may be installed for an appurtenance] determines the overall height of the structure and thus the intermediate levels. If lighting is installed on a tower and an appurtenance is later installed, additional lighting may be applied to address the appurtenance without changing the location of lighting originally installed on the tower. The additional lighting, however, is designed to flash synchronously with the original lighting. This is intended for appurtenances not significantly more than 12 m. The lighting should be modified if the addition to the object is significantly more than 12 m in height.
(effective 2016/03/01)

(2) Top Level

One or more light units are installed at the highest point of a skeletal structure to provide 360-degree coverage ensuring an unobstructed view.

(3) Intermediate Levels

At an intermediate level of a skeletal structure, two CL-865 beacons are mounted outside, at diagonally or diametrically opposite positions of the intermediate level.

(4) Lowest Level

At the lowest level of light units of a skeletal structure:

(a) the light units may be installed at a higher elevation than that required under this section for the structure, if the surrounding terrain, trees, or any adjacent building would obscure the light units; and
(effective 2016/03/01)

(b) in circumstances determined by a risk evaluation, the light units may be omitted.

Figure 6-1: Medium Intensity White Flashing Lighting System; Configuration D
(effective 2016/03/01)

(5) ) Structures 150 m AGL or Less
(effective 2016/03/01)

When white lights are used during nighttime and twilight only, marking is required for daytime. When operated 24 hours a day, other methods of marking and lighting are not required.

(6) Structures Exceeding 150 m AGL
(effective 2016/03/01)

The lights should be used during nighttime and twilight and may be used 24 hours a day. Marking is always required for daytime.

(7) Appurtenances

An appurtenance is lighted in accordance with the requirements specified in subsection 5.3(3), except as far as the use of the CL-865 light in place of CL-864 light is concerned.

6.5 Chimneys, Flare Stacks, and Similar Solid
Structures

(1) Lighting Levels and Location

The number of levels of light units required to be installed on a chimney, a flare stack or similar solid structure is determined in accordance with Figure 6-1.

(2) Number of Light Units per Level

The number of light units required to be installed on each level of a solid structure referred to in subsection (1), is determined in accordance with Table 5-1.

6.6 Hyperbolic Cooling Towers

A hyperbolic cooling tower is lighted in accordance with the requirements specified in section 5.4.

6.7 Prominent Buildings and Similar Extensive Obstructions

When objects within a group of obstructions are approximately the same overall height above the surface and are located a maximum of 45 m apart, the group of obstructions may be considered an extensive obstruction. Install light units on the same horizontal plane at the highest portion or edge of prominent obstructions. Light units are placed to ensure that the light is visible to a pilot approaching from any direction. Lights are displayed to indicate the extent of the obstruction as follows:
(effective 2016/03/01)

(1) Structures 45 m or Less in All Horizontal Directions
(effective 2016/03/01)

(a) Display at least one light on the highest point at each end of the axis of the obstruction.

(b) If (a) above is impractical because of the overall shape, a double obstruction light is displayed in the centre of the highest point.

(2) Structures Exceeding 45 m in at Least One Horizontal Direction
(effective 2016/03/01)

(a) Display at least one light for each 45 m or fraction thereof, of the overall length of the major axis.

(b) At least one of these lights required in (a) is displayed on the highest point at each end of the obstruction.

(c) Additional lights are displayed at approximately equal intervals not to exceed 45 m on the highest points along the edge between the end lights.

(d) If an obstruction is located near a landing area and two or more edges are the same height, the edge nearest the landing area is lighted.

(3) Structures Exceeding 45 m AGL
(effective 2016/03/01)

(a) Lights are installed on the highest point at each end.

(b) At intermediate levels, lights are displayed for each 45 m, or fraction thereof.

(c) The vertical position of these lights is equidistant between the top lights and the ground level as the shape and type of obstruction will permit.

(d) One light of (c) is displayed at each outside corner on each level with the remaining lights evenly spaced between the corner lights.

Information Note: Due to the glare factor, caution should be used in the application of strobe-type medium intensity white flashing lights.
(effective 2016/03/01)

6.8 Bridges

A bridge is lighted in accordance with the requirements specified in section 5.6.

CHAPTER 7   HIGH INTENSITY WHITE SYSTEM, CONFIGURATION "B" and "C"
(effective 2016/03/01)

7.1 Scope 

Chapter 7 governs obstruction lighting that uses a configuration "B" and "C" lighting system.

7.2 Application

When a high intensity white flashing lighting system is operated 24 hours a day, the marking requirements and the other applicable lighting requirements for an obstruction may be omitted.

Information Note:  This lighting system is not recommended on structures 150 m AGL or less, unless a risk evaluation shows otherwise.

7.3 Characteristics

(1) Photometrics

The photometric output of a high intensity white flashing lighting system is in accordance with Table 13-2.

(2) Control

The lighting system is controlled in accordance with Table 13-1 for day, twilight and night modes of operation.

7.4 Installation

(1) Vertical Aiming

In order to avoid potential glare problems, the vertical aiming angle of a CL-856 light unit used in a high intensity white flashing system is as follows:

Location

(a) the unit is adjusted to compensate for its height above ground, in accordance with Table 7-1; and

Table 7-1: Vertical Aiming of HI Light Units
(effective 2016/03/01)

Location of light unit AGL
(metres)
Beam angle adjustment
(degrees)

x = 150 m

0

122 = x > 150 m

1

92 = x > 122 m

2

92 m > x

3

Terrain

(b)

  1. (i) where terrain, nearby residential areas, or other situations dictate, the light beam of a light unit may be further elevated above the horizontal,

  2. (ii) the main beam of light unit located at the lowest level of a building, structure or object shall not strike the ground closer than 5 km from the building, structure or object,

  3. (iii) if additional adjustments are necessary, light units may be individually adjusted upward, in 1 degree increments, starting at the bottom of the building structure or object,

  4. (iv) excessive elevation, however, may reduce conspicuousness by raising the beam above a collision course flight path,

  5. (v) where the lighting system is installed on a building, structure or object located near a highway, waterway, or airport approach area, shielding or vertical or horizontal aiming adjustments, or both, shall be made as necessary to avoid causing glare, and

  6. (vi) adjustment of light units shall not derogate from the conspicuousness requirement set out in section 2.1 of this Standard.

(2) Relocation or Omission of Light Units

Where any light units are obstructed from view by a building, structure or object, including surrounding terrain and trees, the following actions may be taken:

Lowest Level 

(a) In the case of the lowest level of lights:

  1. (i) as shown in Figure 7-1, the light units may be installed at a higher elevation than that required under Chapter 7, and
    (effective 2016/03/01)

  2. (ii) in circumstances determined by a risk evaluation, the light units may be omitted.
    (effective 2016/03/01)

Two Adjacent Structures

(b) As shown in Figure 7-2 and Figure 7-3, in the case of adjacent buildings or structures:
(effective 2016/03/01)

  1. (i) if two buildings or structures are situated within 150 m of each other and their respective light units are installed at similar levels, the light units on the sides of the buildings or structures facing each other may be omitted provided that all lights on both structures flash simultaneously, except for adjacent catenary support structures,

  2. (ii) vertical placement of the lights to either or both structures’ intermediate levels is adjusted to place the lights on the same horizontal plane,

  3. (iii) where one building or structure is higher than the other, one or more complete levels of light units, as the case may be, is installed on that part of the higher building or structure that extends above the top of the lower structure, and

  4. (iv) if the structures are of such heights that their respective levels of lights cannot be placed in identical horizontal planes, the levels of light units are placed such that the centre of the horizontal beam patterns does not face toward the adjacent building or structure.
    (effective 2016/03/01)

Information Note:  For example, based on subparagraph (iv) above, structures situated north and south of each other will have the light units on both structures installed on a northwest/southeast and northeast/southwest orientation.

Three or More Adjacent Structures

(c) the treatment of a cluster of structures as an individual or a complex of structures is determined by way of a risk evaluation, taking into consideration the location, heights, and spacing with other structures.

Figure 7-1: Adjacent Building
(effective 2016/03/01)

Figure 7-2: Lighting Adjacent Structures
(effective 2016/03/01)

Figure 7-3: Lighting Adjacent Structures
(effective 2016/03/01)

7.5 Radio and TV Towers and Similar Skeletal Structures

(1) Top Level

On a radio, TV tower or similar skeletal structure, one level of light units is installed within 3 m of the highest point of the main structure.

(2) Intermediate Levels

On a skeletal structure referred to in subsection (1):

(a) the number of levels of light units to be installed depends on the height of the structure, excluding any appurtenances, and is determined in accordance with Figure 7-4; and
(effective 2016/03/01)

Information Note 1:  The number of levels for the high intensity lights of Configuration B is determined from the height of the main structure excluding any appurtenance. Where the appurtenance exceeds 12 m, a medium intensity light is installed on the top of the appurtenance or within 12 m of the top of the appurtenance and the combination of lighting is Configuration C.
(effective 2016/03/01)

Information Note 2:  It is intended that Configuration C is to address appurtenances that are not significantly in excess of 12 m. Where the appurtenance is significantly in excess of 12 m the Minister may deem a portion of such appurtenance to be considered a part of the main structure and lighting to be provided accordingly.
(effective 2016/03/01)

(b) at least three lights are installed on each intermediate level and mounted to ensure that the effective intensity of the full horizontal beam coverage is not impaired by the structural members.

(3) Appurtenances

Where a skeletal structure has an appurtenance in excess of 12 m in height above it:

(a) a medium intensity white flashing light is installed in accordance with subsection 6.4(5); and

(b) the light referred to in paragraph (a) operates 24 hours a day and flashes simultaneously with the rest of the lighting system installed on the structure.

Figure 7-4: High Intensity White Flashing System - Configuration B and C
(effective 2016/03/01)

7.6 Chimneys, Flare Stacks and Similar Solid Structures

(1) Lighting Levels and Location

Subject to subsection (3), the number of levels of light units required to be installed on a chimney, flare stack or similar solid structure is determined in accordance with Figure 7-4.
(effective 2016/03/01)

(2) Number of Light Units per Level

The number of light units required to be installed on each level of the high intensity white flashing lighting system of a structure referred to in subsection (1), is determined in accordance with Table 5-1.
(effective 2016/03/01)

(3) Hyperbolic Cooling Towers

Where any cooling tower of a nuclear generating station:

(a) is 180 m in height or less AGL, intermediate light levels may be omitted; or

(b) exceeds 180 m AGL in height, a second level of light units is installed approximately at the midpoint of the structure and in a vertical line with the top level of lights.

Figure 7-5: Hyperbolic Cooling Tower
(effective 2016/03/01)

7.7 Prominent Buildings, Structures and Similar Extensive Objects

(1) Individual buildings, structures or objects having a similar height above ground and located not more than 60 m apart within a group of obstructions may be considered as an extensive obstruction for lighting purposes, in which case the group displays CL-856 white flashing light units to indicate the extent of the obstruction as specified in this section.

Information Note:  Owing to the glare factor, caution shall be used in the application of high intensity white flashing lights.

(2) On a structure 60 m or less in both horizontal dimensions, a CL-856 light is displayed in the centre of the highest point.
(effective 2016/03/01)

(3) Structures Exceeding 60 m in any Horizontal Dimension

(a) On a structure exceeding 60 m in any horizontal dimension, CL-856 light units are displayed on:

  1. (i) the highest point at each end of the obstruction, and

  2. (ii) the highest points for each 60 m, or fraction thereof, for the overall length of the major axis.

(b) If the minor axis of a structure exceeding 60 m in one of its horizontal dimensions is 60 m or less in length, the lights referred to in paragraph (a) may be installed as a row along the middle or along either side, as shown in Figure 5-3.

(4) If the obstruction exceeds 60 m in both horizontal dimensions, light units should be equally spaced along the overall perimeter of the obstruction at intervals of 60 m or fraction thereof.
(effective 2016/03/01)

(5) Structures Exceeding 150 m AGL

(a) Top Lights - A CL-856 white flashing light unit is installed on the highest point at each end of a structure exceeding 150 m AGL in height.

(b) At intermediate levels of the structure,

  1. (i) a CL-856 white flashing unit is displayed for each 150 m or fraction thereof,

  2. (ii) the vertical position of the intermediate lights is equidistant between the top lights and the ground level as the shape and type of obstruction will permit, and

  3. (iii) a CL-856 white flashing unit is displayed at each outside corner on each level with the remaining lights evenly spaced between the corner lights.

CHAPTER 8   DUAL RED/WHITE MEDIUM INTENSITY SYSTEM,
CONFIGURATION "E"

(effective 2016/03/01)

8.1 Scope 

Chapter 8 governs obstruction lighting that uses a configuration "E" lighting system consisting of CL­810 steady burning red and CL-864 flashing red obstruction light units for nighttime operation and CL-865 medium intensity white flashing light units for daytime and twilight operation.

Information Note:  This lighting system may be used in lieu of operating a CL-865 medium intensity white flashing system at night, in order to avoid glare complaints particularly in populated urban areas.

8.2 Application

(1) The light units of the system are installed as required by the relevant provisions of:

(a) Chapter 4 for lighting in general;

(b) Chapter 5 for red lighting; and

(c) Chapter 6 for medium intensity lighting.

(2) The number of light levels needed is obtained from Figures 5-1 and 6-1 for the applicable components of the lighting system.

(3) Where the lighting is medium intensity light is a combined CL-865/CL-864 light unit, and it is intended that the CL-865 not be installed less than 60m height, the CL-864 is at the same location as the CL-865.
(effective 2016/03/01)

8.3 Operation

The lighting system is operated such that:

(a) both the red CL-864/CL-810 and white CL-865 systems are not operated at the same time;
(effective 2016/03/01)

(b) there is no more than a 2-second delay when changing from one system to the other; and

(c) outage of one of two lamps in the uppermost CL-864 red flashing beacon or outage of any uppermost red light causes the white CL-865 obstruction lighting system to operate in its specified "night" step intensity.
(effective 2016/03/01)

Information Note: The operation is such that the CL-865 are ON for daytime [where there is no painting] and twilight; the CL-864 and CL-810 are ON for nighttime.
(effective 2016/03/01)

8.4 Control Device

The lighting system is controlled such that:

(a) a photocell device causes a change of operation from red to white lighting with an increase and decrease of the ambient light level;

(b) the system automatically changes from white to red and subsequently from red to white when the northern sky illuminance, as indicated in Table 13-1, goes through the transitions of twilight to night and night to twilight respectively; and

(c) where a malfunction requires the CL-865 white lighting system to be operated during the night, the device causes operation at the lower intensity level.
(effective 2016/03/01)

8.5 Antenna or Similar Appurtenance Light

When a structure utilizing this dual lighting system is topped with an antenna or similar appurtenance exceeding 12 m in height above the structure:

(a) a CL-865 medium intensity white flashing light and a CL-864 red flashing beacon is placed within 12 m from the tip of the appurtenance;

(b) the CL-865 white light operates during daytime and twilight and the red light during nighttime; and

(c) the lights required in paragraphs (a) and (b) flash simultaneously with the rest of the lighting system.

8.6 Omission of Marking

When medium intensity white CL-865 lights are operated on a structure 150 m AGL or less during daytime and twilight, the markings required under this Standard may be omitted on the structure.
(effective 2016/03/01)

CHAPTER 9   DUAL RED/WHITE HIGH INTENSITY SYSTEM, CONFIGURATION "F"
(effective 2016/03/01)

9.1 Scope

Chapter 9 governs obstruction lighting that uses a configuration "F" lighting system referred to in Table 4-2.

Information Note:  This lighting system may be used in lieu of operating a white flashing lighting system at night. There may be urban areas where the use of high intensity lights at night may cause environmental complaints.
(effective 2016/03/01)

9.2 Light Units

CL-810 and CL-864 red light units shall be used for night time lighting and CL-856 high intensity white flashing light units shall be used for daytime and twilight lighting.

9.3 Installation

The light units required under section 9.2 are installed in accordance with the relevant provisions of Chapter 4 for lighting in general, of Chapter 5 for red CL-864/CL-810 lighting and Chapter 7 for high intensity white CL-856 flashing lighting.
(effective 2016/03/01)

9.4 Operation

A configuration "F" lighting system:
(effective 2016/03/01)

(a) is operated in accordance with the requirements of:
(effective 2016/03/01)

  1. (i) Chapter 4 for lighting in general,

  2. (ii) Chapter 5 for red lighting, and

  3. (iii) Chapter 7 for high intensity white flashing lighting;

(b) does not have both red and white lighting systems operating at the same time; however, there is no more than a 2-second delay when changing from one colour of lighting system to the other; and
(effective 2016/03/01)

(c) where an outage of one of two lamps in the uppermost CL-864 red beacon or an outage of any uppermost red light unit occurs, have the white CL-856 lighting switched on and operating in its specified night mode of intensity.
(effective 2016/03/01)

9.5 Control Device

The light intensity of a configuration "F" lighting system is controlled by a photocell device set to operate in accordance with Table 13-1 for transition between day, twilight and night.
(effective 2016/03/01)

9.6 Antenna or Similar Appurtenance Light

(1) Where a configuration "F" lighting system is used on a building, structure or object that is topped with an antenna or similar appurtenance exceeding 12 m in height above it, both a CL-864 medium red flashing and a CL-865 medium intensity white flashing light unit is placed within 12 m from the tip of the appurtenance.

(2) The white light unit referred to in subsection (1) operates during daytime and twilight, and the red light unit during night time.

9.7 Omission of Marking

When high intensity white flashing light units are operated during daytime and twilight, any day marking otherwise required under Chapter 3 to be displayed on the building, structure or object may be omitted.

CHAPTER 10   MARKING AND LIGHTING OF CATENARIES

10.1 Scope

Chapter 10 governs obstruction marking and lighting of a catenary wire and a catenary support structure.

Information Note: The catenaries described in this chapter with respect to river crossings. The same requirements for making and lighting could be applied to other catenaries over such as valleys.
(effective 2016/03/01)

10.2 Marking of Catenary Support Structures

A support structure of a power line is painted in alternate bands of orange and white in accordance with subsection 3.5(3), and is clear of trees and brush insofar as practicable. [refer to information note in section 2.1.]
(effective 2016/03/01)

10.3 Markers
(effective 2016/03/01)

(1) Structure Markers
(effective 2016/03/01)

Markers are used to highlight support structures when it is impractical to make the structures conspicuous by painting. Markers may also be used in addition to aviation orange and white paint when additional conspicuity is necessary for aviation safety. They should be displayed in conspicuous positions on or adjacent to the structures so as to retain the general definition of the structure. The markers are recognizable in clear air from a distance of at least 1200 m and in all directions from which aircraft are likely to approach. The markers are distinctively shaped, i.e., spherical or cylindrical, so they are not mistaken for items that are used to convey other information. They are replaced when faded or otherwise deteriorated.
(effective 2016/03/01)

(2) Shore Markers
(effective 2016/03/01)

Where the marking of a support structure would not clearly indicate the presence of a catenary over a waterway, shore markers are displayed as indicated in Figure 10-1, and:
(effective 2016/03/01)

(a) painted aviation orange and white

(b) either of:
(effective 2016/03/01)

  1. (i) a panel type, designed as a 6 m square panel with a 5 m diameter aviation orange dot, or

  2. (ii) a pole type.

10.4 Catenary Markers

Spherical markers are displayed on a catenary, as indicated in Figure 10-1 and as specified below, unless equivalent markings are approved by the Minister as a result of a risk assessment:

Figure 10-1: Catenary Markers
(effective 2016/03/01)

(1) Dimensions and spacing

Each marker has the following diameters and associated spacings on the catenary:

(a) 50 cm diameter and 30 m spacing;

(b) 75 cm diameter and not more than 45 m spacing;
(effective 2016/03/01)

(c) 90 cm and not more than 60 m spacing;
(effective 2016/03/01)

(d) 150 cm diameter and 90 to 120 m spacing;

(e) other dimensions or shapes are used provided the projected area of such markers is not less than that presented by a spherical marker or can be recognized in clear air from a distance of at least 1000 m; and
(effective 2016/03/01)

(f) 50 cm diameter installed in critical areas near runway ends at a spacing of 10 m to 15 m.
(effective 2016/03/01)

(2) Minimum Quantity

Where the length of the catenary span is less than twice the spacing, depending on the size of marker as that indicated in subsection (1), not less than two markers are used.

(3) Location

Markers are displayed:

(a) on the highest wire or by other means at the same height; or

(b) where there is more than one wire at the highest level, the markers may be installed alternately along each wire, as indicated in Figure 10-1, as long as the apparent distance between adjacent markers as seen by the pilot [horizontally and perpendicular to the wires] meets the spacing standard.
(effective 2016/03/01)

Information Note:  This method will allow the weight and wind loading factors to be distributed.

(4) Colour Pattern

Markers have the following colour patterns:

(a) on overhead wires, they are marked by alternating solid colour spheres of orange and white;

(b) an orange marker is placed at each end of the overhead wire and its spacing adjusted to accommodate the rest of the markers; and

(c) when less than four markers are needed, they are all orange.

10.5 Omission of Marking

Marking of a catenary wire or a support structure may be omitted, where:

  1. (a) the height of the support structure is 150 m AGL or less, and CL-866 lights are installed on the support structure and operated 24 hours a day; or

  2. (b) CL-857 high intensity white flashing light units are installed on the support structure and operated 24 hours a day.

10.6 Lighting of Catenary Wires

(1) Light units are installed along a catenary wire, either separately or in combination with a day marker, provided that the light units are:

(a) used on transmission line catenary near airports, heliports, across rivers, canyons, lakes, and similar geographical features;

(b) visible by a pilot from any normal angle of approach;

(c) meet the requirements specified for the CL-810 light unit;

(d) installed on the highest energized line;
(effective 2016/03/01)

(e) located within 6 m of the day marker if the light unit is separate from the day marker; and

(f) spaced at the same interval as that required for the day markers on the same catenary.

(2) Lighting of catenary wires is not required where lighting in accordance with section 10.7 or 10.8 is installed, unless otherwise determined following a risk assessment.

Information Note: Where catenary wire lights and markers cannot be installed on the catenary itself [e.g. a gondola lift], installation may be made on a separate line in a manner that provides an equivalent level of safety.
(effective 2016/03/01)

Figure 10-2: Catenary Wire Lights
(effective 2016/03/01)

10.7 Lighting of Catenary Support Structures
(effective 2016/03/01)

(1) Where a support structure or a power line crossing are assessed by the Minister, as a result of an Aeronautical Evaluation, as likely to be inadequately indicated by painting and markers specified in Chapter 10, the support structure is lighted in daytime by medium CL-866 or high intensity CL-857 white flashing light units as follows and as illustrated in Figure 10-3:
(effective 2016/03/01)

(a) The lighting is operated at night at reduced intensity.
(effective 2016/03/01)

(b) Where residential complaint would result from the use of white lighting, a dual system of CL-866/CL-885 or CL-857/CL-885 may be installed.
(effective 2016/03/01)

(c) The lighting systems are identified as Configurations S1, S2, S3, S4 and S5 as listed in Table 13­2 and illustrated in Figure 10-4.
(effective 2016/03/01)

(d) Where a catenary wire crossing requires three or more supporting structures, the inner structures are equipped with enough light units per level to provide a full 360 degree coverage.
(effective 2016/03/01)

(e) High intensity CL-857 or dual high intensity CL-857/CL-885 systems are not recommended on structures 150 m or less in height unless an aeronautical study shows otherwise.
(effective 2016/03/01)

Figure 10-3: Catenary Flashing Lights
(effective 2016/03/01)

Figure 10-4: Catenary Configurations
(effective 2016/03/01)

(2) Support Structures 150 m AGL or less

(a) When medium intensity white lights CL-866 are operated 24 hours a day, or when a dual red/medium intensity system CL-866 daytime & twilight/CL-885 nighttime is used, marking is omitted.
(effective 2016/03/01)

(b) When using a medium intensity white light CL-866 or a flashing red light CL-885 during twilight or nighttime only, painting is used for daytime marking.
(effective 2016/03/01)

(3) Support Structures exceeding 150 m AGL

(a) When high intensity white lights CL-857 are operated 24 hours a day, or when a dual red/high intensity system CL-857 daytime and twilight/CL-885 nighttime is used, marking can be omitted.
(effective 2016/03/01)

(b) When a flashing red obstruction light CL-885, a medium intensity CL-866 flashing white lighting system or a high intensity white lighting system CL-857 is used for nighttime and twilight only, painting is used for daytime marking.
(effective 2016/03/01)

(4) Levels of Light Units

The lighting system includes light levels displayed as follows:

(a) a system of three levels of sequentially flashing light units is installed on each supporting structure or adjacent terrain as follows:

  1. (i) at the top of the structure,

  2. (ii) at the lowest point in the catenary, and

  3. (iii) approximately midway between the other two light levels and at least 15 m from the other two levels, except that the middle light level may be deleted when the distance between the top and the bottom light levels is less than 30 m,

(b) the maximum vertical spacing tolerance allowed to accommodate structural limitations is 20 percent of the uniform spacing of the bottom and middle light units, and

(c) if the base of the supporting structure is higher than the lowest point in the catenary, such as a canyon crossing, the required light units are installed on the adjacent terrain at the level of the lowest point in the catenary.

(5) Light Coverage

The photometric coverage requirements for the light units are:

(a) in the case of the top level of light units:

  1. (i) one or more lights are installed, subject to subparagraph (ii), at the top of the structure to provide 360-degree coverage ensuring an unobstructed view to a pilot from any normal angle of approach,
    (effective 2016/03/01)

  2. (ii) if the installation presents a potential danger to maintenance personnel, or when necessary for lightning protection, the top level of light units may be mounted not more than 6 m below the highest point of the structure, provided that due consideration is given to the overall obstacle avoidance distances referred to in section 2.1, and

(b) in the case of the middle and bottom levels of light units:

  1. (i) the light units at the middle level and bottom level are installed so as to provide a minimum of 180-degree coverage cantered perpendicular to the flyway,

  2. (ii) where a catenary crossing is situated near a bend in a river, canyon or similar geographical feature, or where it is not perpendicular to the flyway, the horizontal beam is directed to provide the most effective light coverage to warn pilots approaching the catenary wires from any normal angle of approach, and

  3. (iii) where a catenary involves three or more supporting structures, the inner structure or structures are equipped with enough light units per level to provide 360-degree coverage.

(6) Flash Sequence

The lighting system flashes as follows:

  1. (a) each light unit has a flash frequency of 60 flashes per minute or 1 second per flash cycle (± 5 percent),
  2. (b) the flash sequence of the levels of light units is middle, top, and then bottom,
  3. (c) the interval between top and bottom flashes is about twice the interval between middle and top flashes, and
  4. (d) the interval between the end of one sequence and the beginning of the next is about 10 times the interval between middle and top flashes.

(7) Synchronization

On the lighting system used for associated catenary support structures:

(a) the corresponding light levels flash simultaneously, if practicable, and

(b) where three or more supporting structures are involved and the inner structure or structures are equipped with enough light units per level to provide 360-degree coverage, the light units for each level flash simultaneously.

(8) Photocell Control

Where a medium or high intensity lighting system is used for a catenary crossing, the light intensity of the system is automatically controlled by photocell devices whose day, twilight and night transition settings conform to the specifications set out in Table 13.
(effective 2016/03/01)

(9) Photometric Characteristics

The photometric characteristics of the lighting system are in accordance with the requirements set out in Chapter 13.

10.8 Lighting with use of Aircraft Detection System (ADS)
(effective 2016/03/01)

As determined by a risk assessment and approved by the Minister, Where an Aircraft Detection System (ADS) is installed as specified in Chapter 15, each support structure may be lighted by one of the following medium intensity lighting systems as illustrated in Figure 10-2b:
(effective 2016/03/01)

(a) a CL-866 medium intensity white flashing white lighting system, or

(b) a CL-866/CL-885 dual medium intensity flashing lighting system.

Information Note: The reduced lighting with use of ADS is limited to short catenaries where a single light on each support tower is determined as sufficient. Normally, full sequenced lighting as specified in article 10.7 would be installed and controlled by the ADS.
(effective 2016/03/01)

Figure 10-5: Catenary Flashing Lights with ADS
(effective 2016/03/01)

10.9 Site Maintenance / Clearance
(effective 2016/03/01)

The area in the vicinity of the catenary and support structure base should be clear of all items and/or objects of natural growth that could interfere with the line-of-sight between a pilot and the obstacle marking/lighting.

CHAPTER 11   MARKING AND LIGHTING OF TETHERED OBJECTS
(effective 2016/03/01)

11.1 Scope

(1) Chapter 11 governs the marking and lighting of tethered objects including moored balloons and kites.
(effective 2016/03/01)

(2) This chapter does not address tethered objects intended to be released prior to full extension of the tether, such as glider winching operations for which the ground attached tether is exposed in the air for a short period of time.
(effective 2016/03/01)

11.2 Tethered Objects Less than 150 m AGL
(effective 2016/03/01)

11.2.1 Application

A balloon that is 1.8 m or more in diameter or exceeds 3 cubic metres of gas capacity, or a kite weighing more than 2.27 kg are marked and lighted in accordance with the requirements specified in Chapter 11.

11.2.2 Markers

Markers are attached, during daytime, to the mooring lines of a balloon or to the tether cable of a kite in accordance with this section.

(1) Location

Markers are displayed at not more than 15 m intervals along the mooring lines of the balloon or the tether cable of the kite, beginning at 45 m from the point of attachment on the ground.

(2) Characteristics

Markers required under subsection (1) are:

(a) rectangular in shape, 0.15 m wide and 3.0 m in length; and

(b) of the following colour patterns:

  1. (i) solid orange, or
  2. (ii) of two triangular sections, one of aviation orange and the other aviation white, combined to form a rectangle.

11.2.3 Lighting

At night, a moored balloon or a kite is equipped with the lighting devices specified in this section.

(1) Location

(a) Lights having the characteristics specified in subsection (2) are located on the top of the object in a fashion as to be viewable from all directions, except that where the dimensions of the object are in excess of 45 m, additional lights of the same type are installed on the top, nose section, tail section, and on the mooring lines or tether cable approximately 5 m below the balloon or kite, so as to define its shape and size; and

(b) Additional lights are equally spaced along the mooring line or tether cable for each 107 m, or fraction thereof, commencing at 90 m AGL.

(2) Characteristics

For operations from 90 m AGL to 150 m AGL, red flashing or white flashing lights of 32.5 effective candelas are installed on the moored balloon and on its mooring lines, or on the tether cable of the kite.
(effective 2016/03/01)

(3) Control

Lighting required on a moored balloon or on a kite is provided with a means of control such as, for instance a photocell, for day and night time operation in accordance with Table 13-1.

11.3 Tethered Objects more than 150m AGL
(effective 2016/03/01)

Tethered objects of more than 150m AGL are provided with day and night protection using white high intensity CL-856 lights, or dual white high intensity / red medium intensity CL 856/CL-864 lights located and operated as for skeletal objects as detailed in Chapter 7 and Chapter 9.
(effective 2016/03/01)

CHAPTER 12   MARKING AND LIGHTING OF WIND TURBINES AND WIND FARMS
(effective 2016/03/01)

12.1 Scope

Chapter 12 governs the marking and lighting of a wind turbine and a wind turbine farm.

Information Note 1:  The definition of wind farm is based on the premise that the installation of three wind turbines is the first instance for which omission of lighting might be made. Since the exterior wind turbines [on the perimeter] of a wind farm are to be lighted, a grouping of only two wind turbines would require that both be lighted. In the case of three wind turbines lighting of the inner wind turbine may be omitted depending upon spacing.

Information Note 2:  The application of these requirements can vary in accordance with the provisions of this Standard depending on terrain features, geographic location, overall layout of the structures, and normal angles of approach.

Information Note 3:  The provision of lighting on wind turbines and wind farms should be done in a fashion as to minimize the possibility of bird fatalities and interference with nighttime astronomical study.

12.2 Wind turbines of Total Height Equal to or Less than 150 m

(1) Marking Requirements - Day Protection
(effective 2016/03/01)

(a) For a single wind turbine and wind turbines of a wind farm, having a solid silhouette, the rotor blades, nacelle and upper 2/3 of the supporting mast are painted a white or an off-white colour.
(effective 2016/03/01)

(b) A wind turbine having a lattice-work support mast has the mast painted in bands of orange and white as for skeletal structures.
(effective 2016/03/01)

Information Note:  The above specified colours can be found in the RAL colour system as ...

  1. orange - 2009
    (effective 2016/03/01)
  2. white - 9010
  3. off-white - 7035 (light grey)

(2) Lighting Requirements - Twilight and Night Protection
(effective 2016/03/01)

For Night Protection, a single wind turbine and wind turbines of a wind farm are lighted as illustrated in Figure 12-1 and as follows:

(a) For a single wind turbine:

  1. (i) A wind turbine is lighted with use of a CL-864 light unit for twilight and nighttime operation for horizontal turbines or a CL-865 light unit for daytime, twilight and nighttime operation for vertical turbines as shown in Figure 12-1.
    (effective 2016/03/01)
  2. (ii) The lighting fixtures required under subparagraph (i) are mounted to ensure an unobstructed view by a pilot approaching from all angles of aircraft approach.

(b) For a wind farm:

  1. (i) The group of wind turbines composing a wind farm is indicated to pilots by installation of CL-864 medium intensity red flashing beacons on specified wind turbines on the perimeter of the wind farm.
  2. (ii) The "wind farm indicators" of subparagraph (i) are located so as to define the wind farm perimeter and spaced at a distance of approximately 900 m.
    (effective 2016/03/01)
  3. (iii) In addition to the wind farm indicators of subparagraph (ii) the dominant [highest height above mean sea level (AMSL)] wind turbine within the wind farm is also required to be lighted. This requirement for lighting is dependent upon the degree of dominance deemed to produce a hazard to air navigation. The Minister may require lighting on more than one inner wind turbine, depending upon the dimensions of the wind farm.
    (effective 2016/03/01)
  4. (iv) A tower or other structure within the wind farm, which in being lighted provides the same level of safety, may be used for installation of a wind farm indicator.
  5. (v) Because of the variation in configuration of wind farms, the provision of lighting is also subject to a risk assessment taking into account such factors as the general profile of the group, the location of the wind farm in relation to nearby aerodromes or recognized VFR flight routes, and the anticipated air traffic.
  6. (vi) All indicator lighting provided for a wind farm flashes simultaneously.

Figure 12-1: Lighting Wind turbines; Heights up to 150 m AGL
(effective 2016/03/01)

12.3 Wind turbines of Total Height Exceeding 150 m

(1) Marking Requirements - Day Protection
(effective 2016/03/01)
Refer 12.2(1)

(2) Lighting Requirements
(effective 2016/03/01)

For wind turbines of 150 m to 315 m in overall height:

(a) Two CL-864 lights are installed on the nacelle, as illustrated in Figure 12-2. Only one light operates at a time; the second light serving as backup in case of failure of the operating light. The lights are installed on top of each other so that the output of operating light is not blocked by the standby light for angles of approach.

(b) At least three CL-810 lights are installed for an intermediate level at half the nacelle height and configured to flash at the same rate as the light on the nacelle.

(c) The lights are installed:

  1. (i) in such a manner as to provide an unobstructed view for aircraft approaching from any direction.

  2. (ii) as "wind farm indicators" according to subparagraphs 12.2(2)(b)(ii) and (iii).

Information Note: The above standard does not address wind turbines of more than 315 m. For wind turbines of more than 315 m of overall height, additional marking and lighting may be required.
(effective 2016/03/01)

Figure 12-2: Lighting Wind turbines; Heights 150 m to 315 m
(effective 2016/03/01)

(3) The provision of marking and lighting for wind turbines higher than 315 m is determined through means of a risk assessment.
(effective 2016/03/01)

12.4 Continued Illumination

The lighting provided for a wind turbine or wind farm is so designed such that it can draw power from the electrical grid for continued illumination even though the wind turbine on which it is mounted ceases operation.

Information Note: The above standard is based upon the premise that the lighting of a non-operating wind turbine can be provided with power from the grid when the wind turbine itself is not operating to generate power. However, the standard recognizes that continued illumination will not be possible should the electrical grid itself fail.
(effective 2016/03/01)

12.5 Temporary Lighting During Construction
(effective 2016/03/01)

In order to ensure conspicuity of turbines at night during construction, all turbines are lit with temporary lighting once they reach a height of 60 m or greater until such time the permanent lighting configuration is turned on. As the height of the structure continues to increase, the temporary lighting is relocated to the uppermost part of the structure. The temporary lighting may be turned off for periods when it would interfere with construction personnel. If practical, permanent CL-864 and CL-810 obstruction lights are installed and operated at each level as construction progresses. At least two CL-810 fixtures are used to light the structure during the construction phase. The lights are positioned to ensure that a pilot has an unobstructed view of at least one light at each level.

12.6 MET Towers (meteorological towers)
(effective 2016/03/01)

MET towers that are used to measure the wind resource available for wind farms may present a hazard to aircraft engaging in low level flight for aerial application of pesticides and other products. As illustrated in Figure 12-3, MET towers that are 60 m or more in height comprise:

(a) marker balls on the outer guy wires near the top of the tower;

(b) a mast of the tower is painted in a banded pattern as stipulated in subsection 3.5(3); and

(c) high visibility sleeves on the outer guy wires close to the anchor points, but at a height above the expected crop/vegetation canopy.

Information Note: It is recommended that MET towers less than 60 m in height be provided with balls on the guy wires and the mast be painted in a banded pattern.
(effective 2016/03/01)

Figure 12-3: MET Tower Marking
(effective 2016/03/01)

CHAPTER 13   OBSTRUCTION LIGHTING CHARACTERISTICS

13.1 Scope

Chapter 13 governs the overall technical characteristics of obstruction lighting equipment required under this Standard.

13.2 Equipment Specification

The specifications covering electrotechnical requirements of obstruction lighting equipment are contained in Appendix B.

13.3 Photometrics

The photometric output of obstruction light units required under this Standard is in accordance with Table 13-4 for fixed lights and Table 13-5 for flashing lights. Figures 13-1 and 13-2 provide an illustration of these photometric requirements.
(effective 2016/03/01)

13.4 Photocell Control

Red and white obstruction lighting systems are operated by means of a control device adjusted so the lights are turned on and off and change intensity steps when the northern sky illuminance on a vertical surface transitions through day-to-twilight and twilight-to-night levels according to the Tables 13-1 and 13-2.
(effective 2016/03/01)

Table 13-1:  Table 13-1: Photocell Control Settings for Northsky Illuminance
(effective 2016/03/01)

Operational transition Northsky illuminance range
From To from footcandles (lux) to footcandles (lux)

day

twilight

60  (645.8) 35 (376.7)

twilight

Night

5  (53.8) 2 (21.5)

night

twilight

2  (21.5) 5 (53.8)

twilight

Day

35  (376.7) 60 (645.8)

Figure 13-1: Photocell Settings
(effective 2016/03/01)

Table 13-2:  Control Settings
(effective 2016/03/01)

 

 

Intensity setting

Configuration

 

Day

Twilight

Night

A  red lighting system

CL-864

CL-810

off

off

1

1

1

1

B  HI white

CL-856

3

2

1

C  HI white (with L-865

appurtenance light)

CL-856

CL-865

3

2

2

2

1

1

D  MI white (no paint)

CL-865

2

2

1

D  MI white (with paint)

CL-865

off

2

1

E  dual MI white/red (no paint)

 

 

CL-865

CL-864

CL-810

2

off

off

2

off

off

off

1

1

E  dual MI white/red (with paint)

 

 

CL-865

CL-864

CL-810

off

off

off

2

off

off

off

1

1

F  dual HI white/red

 

 

 

CL-856

CL-865

CL-864

CL-810

3

2

off

off

2

2

off

off

off

off

1

1

Catenary Configuration

 

 

 

 

S1 MI white,

CL-866

2

2

1

S2 dual MI white/red (no paint)

 

CL-866

CL-885

2

off

2

off

off

1

S2 dual MI white/red (with paint)

 

CL-866

CL-885

off

off

2

off

off

1

S3 HI white

CL-857

3

2

1

S4 dual HI white/red

 

CL857

CL-885

3

off

2

off

off

1

S5  MI red

CL-885

off

1

1

LI = low intensity
MI = medium intensity
HI = high intensity

Information Note: The premise for lighting control is that where a red lighting system alone is installed, its operation is for twilight and night. Where a dual white/red system is installed, the white lighting is operated in day and twilight and the red lighting is operated only for night time. (effective 2016/03/01)

Table 13-3:  Characteristics of obstacle lights
(effective 2016/03/01)

Light Type

Colour

Signal type

flash rate
(fpm)

Nominal intensity (cd)

Intensity Settings

Light Distribution
Table

LI  CL-810

red

fixed

 

32

1

Table 13-4

MI  CL-865 (e)

white

flashing

40

20, 000

2

Table 13-5

MI  CL-864

red

flashing

20-40

2000

1

Table 13-5

HI  CL-856

white

flashing

40

270,000

3

Table 13-5

HI  CL-857

white

flashing

60

140, 000

3

Table 13-5

Catenary MI CL-866

white

flashing

60

20, 000

2

Table 13-5

Catenary MI CL-885

red

flashing

40

2000

1

Table 13-5

LI = low intensity
MI = medium intensity
HI = high intensity

Table 13-4:  Minimum Intensity and light distribution for low-intensity obstacle lights (Figure 13-2)
(effective 2016/03/01)

 

 

Vertical range (degrees)

Light Type

Minimum intensity Footnote (a)

Lower limit

Upper limit

CL-810

32 cd

+2.5°

+12.5°

13.5a Minimum Effective intensities of flashing lights Footnote (a) (Figure 13-3)
(effective 2016/03/01)

 

 

Vertical elevation angle Footnote (b)

Vertical beam spread Footnote (c)

1

2

3

4

5

6

Light Type

Nominal intensity


0.75*[2]

-1°
0.5*[3]

Beam spread

Intensity
0.5*[3]

CL-856

270,000

200,000

100,000

100,000

CL-857

140,000

100,000

50,000

50,000

CL-864

2000

1500

750

750

CL-865 Footnote (e)Footnote (f)

20,000

15,000

7500

7500

CL-866

20,000

15,000

7500

7500

CL-885

2000

1500

750

750

13.5b Recommended maximum effective intensities of flashing lights Footnote (a)Footnote (d) (Figure 13-3)
(effective 2016/03/01)

 

 

Vertical elevation angle Footnote (b)

Vertical beam spread Footnote (c)

7

8

9

10

11

12

13

Light
Type

Nominal intensity


1.25*[8]

-1°
0.75*[3]

-10°
0.03*[9]

Beam spread

Intensity
0.5*[3]

CL-856

270,000

337,500

150,000

10,125

100,000

CL-857

140,000

175,000

75,000

5250

50,500

CL-864

2000

2500

1125

75

N/A

N/A

CL-865 Footnote (e)Footnote (f)

20,000

25,000

11,250

750

N/A

N/A

CL-866

20,000

25,000

11,250

750

N/A

N/A

CL-885

2000

2500

1125

75

N/A

N/A

Figure 13-2: Low Intensity Photometric Requirement
(effective 2016/03/01)

Figure 13-3: High and Medium Intensity Flashing Photometric Requirement
(effective 2016/03/01)

CHAPTER 14   MAINTENANCE

14.1 Scope

Chapter 14 governs the maintenance of marking and lighting required under this Standard.

14.2 Marking and Markers
(effective 2016/03/01)

(1) The surfaces of a building, structure or object required to be marked with paint, are repainted when the colour changes noticeably or when its effectiveness is reduced by scaling, oxidization, chipping or layers of contamination.

Information Note:  In-Service Aviation Orange Colour Tolerance Charts are available from private suppliers for determining when repainting is required. The colour should be sampled on the upper half of the structure, since weathering is greater there.

Figure 14-1: In-service Aviation Orange Colour Tolerance Chart
(effective 2016/03/01)

(2) Powerline markers are inspected at least once a year to verify presence and continued visibility.
(effective 2016/03/01)

14.3 Lighting

(1) Operating Voltage

To ensure proper candela output:

(a) for light units with incandescent lamps, the voltage provided to the lamp socket shall be within ± 3 percent of the rated voltage of the lamp; or

(b) for light units with strobe [capacitor discharge] lamps, the input voltage to the power supply shall be within ±10 percent of rated voltage of the power supply.

(2) Lamp Replacement

(a) A lamp in a light unit is replaced immediately upon failure or after being operated for not more than 75 percent of its rated life.

(b) A flashtube in a light unit is replaced:

  1. (i) immediately upon failure, or
  2. (ii) when the peak effective intensity falls below specification limits, when the fixture begins skipping flashes or at the manufacturer’s recommended intervals, whichever occurs first.

(3) Fixture Lenses

Owing to the effects of harsh environments, a beacon lens is visually inspected for ultraviolet damage, cracks, crazing, dirt build up or similar forms of degradation, to ensure that the required certified light output has not been adversely affected.

14.4 Removal of Obscuring Effects

Regular inspection takes place and remedial action undertaken to ensure that effects, such as the growth of vegetation, do not obscure the pilot's view of any portion of marking or lighting displayed pursuant to this Standard.

CHAPTER 15   AIRCRAFT DETECTION SYSTEM (ADS)

15.1 Scope

(1) Chapter 15 governs Aircraft Detection Systems (ADS) which are used to turn on obstruction lighting systems upon detection of an approaching aircraft. The system is sensor based and can detect and analyze the flight path [position, altitude, heading and ground speed] of an aircraft so as to determine the possibility of potential collision with an object. If the flight path is such that the aircraft may impact the obstacle, then the obstacle lights are turned on and an audio signal may be transmitted. The purpose of the system is to enable the lighting to be off when not needed [absence of aircraft] and thereby reduce energy consumption and minimize cause for complaint from local residents.
(effective 2016/03/01)

(2) The means of detection is not dependent upon equipment on the aircraft [e.g. a transponder].
(effective 2016/03/01)

15.2 Impact Boundary

(1) The impact boundary is a 3-dimensional boundary around the obstacle approved by the Minister, so as to establish the distance [in terms of seconds] from the location of the detected aircraft to a point of impact on this boundary.

(2) The impact boundary is at a horizontal distance of 30 m to 60 m from the actual physical sides of the obstacle, as shown in Figure 15-1.
(effective 2016/03/01)

Information Note: An impact boundary for a catenary is shown in Figure 15-1. Different shapes of impact boundary may be required for different obstacles. In the case of lengthy or large area objects, more than one ADS sensor may be required.
(effective 2016/03/01)

(3) In vertical dimension, the impact boundary extends 60 m above the highest portion of the obstacle.

15.3 Operation

(1) The system has two primary functions: to turn on the obstacle lights and to emit an audio signal. These functions are performed with respect to the detection of the aircraft within a specified minimum flight time to the impact boundary for both a heading directly towards the impact boundary as well as a potential manoeuvre towards the impact boundary.

(2) The system has the following minimum timings for light and audio signal activation with respect to the speed of the aircraft and time from the impact boundary:

Table 15-1:  Time to Impact Boundary
(effective 2016/03/01)


Aircraft speed
(knots)

Aircraft speed
(metres/second)

Time to Impact Boundary
(seconds)

90

46.3

30

120

61.7

30

165

84.9

30

180

92.6

30

250

128.6

30

(3) Potential Manoeuvre to Impact Boundary

Note d’information : The following addresses the case of aircraft that are not on a direct flight path to impact, but have the potential for impact.

(a) The ADS detects and causes light and audio signal activation per 15.3.2 for aircraft flying in the horizontal plane that would have a potential of impact if it were to conduct a turning manoeuvre of up to 2g. Refer to Figure 15-3.

(b) The ADS detects and causes light and audio signal activation per 15.3.2 for aircraft flying in the horizontal plane that would have a potential of impact if it were to conduct a descent of rate of up to 2.5m/s [500 ft per minute]. Refer to Figure 15-3.

(4) Lighting

(a) Once the lighting is activated upon aircraft detection, the lighting is maintained on for a period of at least 60 seconds.

(b) The lighting for use with ADS is of a design such that it will provide full intensity within 2 seconds of activation.

(5) Audio Signal

(a) The provision of an audio signal is required for catenary crossings where obstacle lighting is on the support structures. The provision of an audio signal for extensive objects such as a wind farm is determined on a site specific basis.
(effective 2016/03/01)

(b) The audio signal consists of a 3 note chime followed by a worded message indicating the type of obstacle as determined locally. For example, for a catenary crossing, the term "power line" may be used. The signal is repeated a total of 6 times for slow speed aircraft and 3 times for high speed aircraft [>250 knots], for a total duration of 12 seconds and 6 seconds respectively.

(c) The audio signal is limited in range so as to not interfere with other non-ADS broadcasts. The limitation of range is tested using standard General Aviation VHF radio and antenna equipment while the ADS VHF transmitter is transmitting a continuous test signal; range limit is where the perceived signal quality comes below level 4.

Information Note 1: A limited range represented by a volume of space defined by a cylinder centred on the ADS unit with a radius of 7 km and height of 1.8 km, is recommended.

Information Note 2: In the radio terminology, the quality of the radio signal is rated on a scale from 1 through 5, where 1 is the worst (unreadable) and 5 is the best. A quality of 4 is fully readable, when below 4 the audio signal is degraded below an acceptable level.
(effective 2016/03/01)

(6) Warning Zones

Information Note: The ADS may be considered to establish "warning zones" around the obstacle based upon the timing for light activation and audio signal transmission in relation to the impact boundary. The warning zone, therefore, extends outward from the impact boundary to the detected aircraft. Since light activation and transmission of the audio signal [if provided] occur simultaneously, the audio warning zone and the light activation warning zone are equal in dimension.
(effective 2016/03/01)

(a) If the aircraft enters the audio signal warning zone, an audio signal is transmitted. If the aircraft remains within this zone no additional audio signals are provided. A new signal will be provided, if the aircraft leaves the zone and then re-enters.

(b) If the aircraft enters the light activation warning zone, the lights are turned on and will continue to be illuminated for the period specified in section 15.3.4. If the aircraft remains within this zone beyond the specified period, the lights will turn off. The lights will be re-activated, when the aircraft leaves the zone and then re-enters.

(7) Frequencies

(a) Audio signal radio broadcasts comply with applicable Innovation, Science and Economic Development Canada guidelines and permit requirements.
(effective 2016/03/01)

(b) If radar is used, the radar frequencies are selected so as to not cause interference with other radar operations.
(effective 2016/03/01)

15.4 Monitoring

The ADS has continuous electronic monitoring to detect failure of the major components.

(a) Sensor or Communications Failure: The occurrence of failure of the sensor or of the communication link to the lights cause the lighting to be turned on continuously, the audio signal deactivated and an alarm given to a 24 hour staffed station. There is provision for immediate issuance of a NOTAM from this station. The communication status and operational status of the system are confirmed at least once every 24 hours.
(effective 2016/03/01)

(b) Obstruction Lights Failure: If a light outage occurs, the audio warning function remains active, the monitoring station is notified and a NOTAM issued. Corrective action is taken as soon as possible to restore the lights.

15.5 Self Test

Unless the system has been activated at least once within a 24 hour period by aircraft, the system is activated for self test at least once within a 24 hour interval to verify the operational status.

15.6 Sensor Unit Backup Power Supply
(effective 2016/03/01)

The radar unit is provided with a battery backup supply having a capacity for 24 hours of operation, to enable communication of external power supply failure to the lights.

15.7 Submission of Application for Use

The design and function of each control device is described in the ADS application. The control device description includes: functionality, selectable features, program modification, maintenance actions, failure/monitoring provisions and any reporting functions. The reportable functions are described and the methodology detailed for accumulating information.

15.8 Commissioning Test

The ADS installation is subject to a commissioning test to verify:

(a) the required performance of the system,

(b) absence of any interferences of a sensor unit based upon radar with other radars in the area, and
(effective 2016/03/01)

(c) that the audio does not present a hazard to other aircraft communications not in proximity to the obstruction hazard.

Figure 15-1: Catenary Crossing - Plan View
(effective 2016/03/01)

Figure 15-2: Catenary Crossing - Profile View
(effective 2016/03/01)

Figure 15-3: Potential Turning/Descent Manoeuvres
(effective 2016/03/01)

APPENDIX A

TRANSPORT CANADA CIVIL AVIATION REGIONS

AERODROMES AND AIR NAVIGATION

Region

Address

Telephone

Pacific

Transport Canada
Suite 620, 800 Burrard St.
Vancouver, British Columbia V6Z 2J8

(604) 666-8777
e-mail: tc.aviationservicespac-servicesaviationpac.tc@tc.gc.ca

Prairie and Northern

for
Alberta,
Saskatchewan,
Manitoba,
Yukon
Nunavut and
NWT

Transport Canada
1100, 9700 Jasper Avenue
Edmonton, Alberta T5J 4E6

1-888-463-0521
e-mail: tc.aviationservicespnr-servicesaviationrpn.tc@tc.gc.ca

Ontario

Transport Canada
4900 Yonge Street, 4th Floor
Toronto, Ontario M2N 6A5

(416) 952-0215
or
1-877-231-2330
e-mail: tc.aviationservicesont-servicesaviationont.tc@tc.gc.ca

Quebec

Transport Canada
700 Leigh Capréol
Dorval, Quebec H4Y 1G7

(514) 633-3252
e-mail: aerodromes.quebec@tc.gc.ca

Atlantic

for
Nova Scotia,
New Brunswick,
Prince Edward Island and
Newfoundland and Labrador

Transport Canada
P.O. Box 42
Moncton, New Brunswick E1C 8K6

 

1-800-387-4999
e-mail: tc.aviationservicesatl-servicesaviationatl.tc@tc.gc.ca

NAV CANADA

If there is a failure of obstacle lighting and it is to be reported through means of a NOTAM, one should contact the NAV CANADA Flight Information Centre in which the object is located.

Nav Canada Flight Information Centre (FIC)

Kamloops

1-866-541-4101

Quebec

1-866-541-4105

Edmonton

1-866-541-4102

Halifax

1-866-541-4106

Winnipeg

1-866-541-4103

Whitehorse

1-866-541-4107

London

1-866-541-4104

North Bay

1-866-541-4109

APPENDIX B

SPECIFICATION FOR OBSTRUCTION LIGHTING EQUIPMENT

Foreword
(effective 2016/03/01)

1. PURPOSE. This appendix to Standard 621 contains Transport Canada specifications for obstruction lighting equipment.

2. EFFECTIVE DATE. Effective 6 months after publication of this specification.

3. CANCELLATION. Appendix B, Specification for Obstruction Lighting Equipment, dated 31 December 2011 is canceled.

4. PRINCIPAL CHANGES

  1. (a) Section 2.0.  Removal of reference to Institute of Electrical and Electronics Engineers (IEEE) publications and Illuminating Engineering Society (IES) publications
  2. (b) Section 3.3.3.  Addition of white colour boundaries for Incandescent Xenon and LED sources
  3. (c) Section 3.3.3.1.  Removal of the section since it is a statement of non-requirement for daytime colour
  4. (d) Paragraph 3.3.4 (b).  Clarification of aiming accuracy of ± one degree
  5. (e) Section 3.3.5.2.2.  Added "the system and individual light unit" to correspond with 3.3.5.1.1(d)
  6. (f) Section 3.3.7.  Removal of section for reason that there is no test criteria and it does not relate to the lighting display
  7. (g) Section 3.4.1.  Removal of duplication of effective intensity formula
  8. (h) Section 3.4.2, Table 1.  In the English edition, correction of microseconds to milliseconds
  9. (i) Section 4.1.  Removed (d) because it is obvious
  10. (j) Section 4.10.  Added verification of monitoring capability

5. COMMENTS OR SUGGESTIONS for improvements to this appendix should be sent to:

Chief, Flight Standards
Transport Canada
ATTN: AARTA
330 Sparks Street,
Ottawa, Ontario, K1A 0N8
Canada

1.0 INTRODUCTION

1.1 Scope

This specification sets forth design and qualification test criteria for obstruction lighting equipment used to increase conspicuity of structures to permit early obstruction recognition by pilots.

1.2 Equipment Classification

Light

Intensity type

colour

Flash rate

Flash Cycle Duration

CL-810

low

red

steady burning

n/a

CL-856

high

white

40fpm

1500ms

CL-857

high

white

60fpm

1000ms

CL-864

medium

red

20 to 40fpm

3000 to 1500ms

CL-865

medium

white

40fpm

1500ms

CL-866

medium

white

60fpm

1000ms

CL-885

medium

red

60fpm

1000ms

fpm = flashes per minute
ms = milliseconds

2.0 REFERENCE DOCUMENTS

2.1 General

It is intended that the following reference documents be used in conjunction with this document:

2.2 Transport Canada

Standard 621 - Obstruction Marking and Lighting

2.3 Federal Aviation Administration (FAA) Advisory Circulars (ACs)

AC 70/7460-1 Obstruction Marking and Lighting

AC 150/5345-43 Specification for Obstruction Lighting Equipment
(effective 2016/03/01)

Information Note: The above FAA circulars are referenced for reason that the Canadian application of obstacle lighting is similar. For example, the CL-810 low intensity obstacle light is similar in application to the FAA L-810). However, the user is cautioned that some of the requirements contained in this specification differ from that in the FAA advisory circular AC 150/5345-43. Lights which have FAA approval, may not be in conformance with Transport Canada requirements. Owners of obstacles in Canada should ensure that the lighting equipment is in conformance with Standard 621.
(effective 2016/03/01)

2.4 Military Standards and Specifications

MIL-STD-810F Environmental Engineering Considerations and Laboratory Tests

MIL-C-7989 Cover, Light-Transmitting, for Aeronautical Lights, General Specification for

2.5 International Civil Aviation Organization (ICAO)

Annex 14 Volume 1, Aerodrome Design and Operations

2.6 Document Sources

Copies of military standards and specifications may be obtained from:

DAPS/DODSSP
Building 4, Section D
700 Robbins Avenue
Philadelphia, PA 19111-5094

Tel:  (215) 697-2179
Website: dodssp.daps.dla.mil

Copies of ICAO documents may be obtained from:

ICAO, Document Sales Unit
999 University Street
Montreal, Quebec, Canada H3C 5H7

Tel:  (514) 954-8022
email:  sales@incao.int
Website: www.icao.int

3.0 EQUIPMENT REQUIREMENTS

3.1 General

This section addresses environmental, design, and photometric requirements for obstruction light equipment. Criteria for selecting the proper obstruction lighting equipment, installation tolerances, and administrative information are in Standard 621, Obstruction Marking and Lighting.

3.2 Environmental Requirements

Obstruction lighting equipment is designed for continuous operation under the following conditions:

(a) Temperature:

  1. Storage/shipping:  -55 degrees Celsius to +55 degrees Celsius
  2. Operating:  -40 degrees Celsius to +55 degrees Celsius

(b) Humidity: 95 percent relative humidity.

(c) Wind: Wind speeds up to 240 kilometres per hour.

(d) Wind-blown Rain: Exposure to wind-blown rain from any direction.

(e) Salt Fog: Exposure to salt-laden atmosphere.

(f) Sunshine: Exposure to solar radiation.

3.3 Design Requirements

3.3.1 Light Unit

(a) Materials used within the light unit are selected for compatibility with their environment.

(b) All plastic lens parts (including gaskets), that are exposed to ultraviolet radiation or ozone gas do not change colour, crack, check, disintegrate, or be otherwise degraded (photometry remains compliant).

(c) Each light unit is an independent unit and flashes at the specified intensity or at its highest intensity when control signals are absent.

3.3.2 Light Covers

(a) Light-transmitting covers for light units are per the requirements in MIL-C-7989. In addition, if plastic covers are used, they are resistant to checking, crazing, or colour changes caused by ultraviolet radiation or ozone gas exposure.

(b) If plastic covers are used, they are resistant to checking, crazing, or colour changes caused by ultraviolet radiation or ozone gas exposure.
(effective 2016/03/01)

3.3.3 Light Colours

The aviation red is per ICAO Annex 14, Volume 1, Appendix 1, Colours for Aeronautical Ground Lights, at operating temperature within the following chromaticity boundaries:
(effective 2016/03/01)

(a) Colour Red

purple boundary

y  =  0.980 - x

yellow boundary

y  =  0.335

(b) Colour White (incandescent and Xenon)
(effective 2016/03/01)

 

1st equation

2nd equation

Yellow boundary

x = 0.500

 

Blue boundary

x = 0.285

 

Green boundary

y = 0.440

y = 0.150 + 0.640x

Purple boundary

y = 0.050 + 0.750x

y = 0.382

(c) Colour White (LED)
(effective 2016/03/01)

Yellow boundary

x = 0.440

Blue boundary

x = 0.320

Green boundary

y = 0.150 + 0.643x

Purple boundary

y = 0.050 +0.757x

3.3.4 Aiming (for CL-856 and CL-857)

(a) Light units have a method for adjustment of the vertical aiming angle between 0 and +8 degrees.

(b) A spirit level or other device is provided as part of each light unit for setting the vertical aiming angle of the light beam with an accuracy of ± degree.

3.3.5 Control Unit

3.3.5.1 White Flashing Obstruction Lighting Systems

(a) The control unit shall set the system's flash rate, intensity and sequence and shall be capable of controlling light units up to a distance of 762 m.

(b) If the control unit or control wiring fails, the light units continue to flash at the flash rate indicated in Table 1.

(c) Failure of an intensity step change circuit shall cause all light units to remain operating at their proper intensity or alternatively to operate at the high intensity step.

3.3.5.1.1 Monitoring.

(a) Each light unit is monitored for FLASH/FAIL status.

(b) FAIL status is defined as either of the following conditions: unit misses four or more consecutive flashes; unit flashes at wrong intensity step during day operation or failure of the continuous movement of the rotating device for rotating type flashing lights.

(c) Monitoring is fail safe (i.e. active signals for FLASH and absence of signals for FAIL).

(d) There is a provision to permit connection to a remote alarm device (supplied by others or as an option) to indicate the system and individual light unit FLASH/FAIL status.

3.3.5.1.2 In addition to the above:

(a) The control unit displays the status of each light unit.

(b) An intensity control override switch is also mounted in the enclosure to manually control light intensity during maintenance or in the event of a photoelectric control malfunction.

3.3.5.2 Red Flashing Obstruction Lighting Systems

(a) The control unit sets the system flash rate and flash sequence. Failure of the flashing circuit causes the light units to energize and operate as steady burning lights.

(b) An override switch is mounted on the control unit to manually control the lights during maintenance or in the event of a lack of a photoelectric control signal.

(c) To ensure proper operation, all flashing red obstruction lights, inclusive of any associated system steady burning red lights, are certified with a control unit whether internal or external to the lighting unit.

3.3.5.2.1 Dual Lighting Systems

(a) The control unit may be a separate unit or incorporated as part of either the white or red obstruction light control unit.

(b) The control unit sets the operating mode for each light unit in the system.

(c) Outage of one of two lamps, or any failure in the device that causes a reduction in intensity of the horizontal beam or results in an outage in the uppermost red beacon (CL-864 unit) or outage of any uppermost red strobe, cause the white obstruction light system to operate in its specified "night" step intensity.

(d) At no time should both red and white systems be on simultaneously.

Note: : This does not apply to a rotating type CL-865 which produces a WWRWWR signal. W = White; R = Red.

(e) An override switch is mounted on the control unit to manually control the operating mode of the system during maintenance or in the event of a lack of a photoelectric control signal.

3.3.5.2.2 Monitoring

(a) Each separate CL-864 light unit and each tier of CL-810 light units is monitored for FLASH/FAIL status.

(b) "FAIL" is defined as outage of any lamp in a CL-864 light unit, outage of any one lamp in a tier of CL-810 light units, or failure of a flasher (steady on and/or total) for a CL-864 light unit.

(c) Monitor signals are fail safe (i.e., active signals for FLASH and absence of signals for FAIL).

(d) There is a provision to permit connection to a remote alarm device, (supplied by others or by the light manufacturer) to indicate the system and individual light unit FLASH/FAIL status.
(effective 2016/03/01)

3.3.6 Input Voltage

(a) The obstruction lighting equipment is designed to operate from the specified input voltage ±10 percent.

(b) Incandescent lamps are operated to within ±3 percent of the rated lamp voltage to provide proper light output.

3.3.7 Optional Arctic Kit

Light systems may be offered with an optional arctic kit to enable operation in temperatures below -40 degrees Celsius.

3.4 Performance Requirements

3.4.1 Photometric

(a) The light units meet or exceed the minimum photometric requirements found in Standard 621.
(effective 2016/03/01)

(b) The effective intensity for single pulse flashing lights is calculated per the following formula:
(effective 2016/03/01)

 

Ie

=          Effective intensity (Candela)

I

=          Instantaneous intensity (Candela)

t1 , t2

=         Times in seconds of the beginning and end of the first pulse flash when the value of I exceeds Ie. This choice of the times maximizes the value of Ie.

 

(c) For discharge type flashing lights, the equipment provides the specified light output at the specified temperature extremes as the input voltage simultaneously varies by ±10 percent from nominal.

(d) The light intensity and beam distribution requirements for obstruction lighting equipment are specified in Chapter 13.

(e) All intensities listed are effective intensities (except steady-burning red obstruction lights) measured at the flash rate specified in Table 1. All incandescent lights will be tested as steady burning lights.

(f) The frequency of the pulses is not less than 50 Hz and the interval tA- t1 does not vary by more than ±5% from the nominal value from pulse to pulse over the simultaneous extremes of temperature and input voltage.

(g) The effective intensity for multiple pulse flashes as used in strobe lights is calculated by: Where:

 

Where:

Ie

=          Effective intensity (Candela)

I

=          Instantaneous intensity (Candela)

t1 , t2

=         Times in seconds of the beginning and end of the first pulse flash when the value of I exceeds Ie. This choice of the times maximizes the value of Ie.

t3 , t4

=         Times in seconds of the beginning and end of the second pulse flash when the value of I exceeds Ie. This choice of the times maximizes the value of Ie.

tn-1 , tn

=         Times in seconds of the beginning and end of the last pulse flash when the value of I exceeds Ie. This choice of the times maximizes the value of Ie.

 

3.4.2 Flash Duration

Flash characteristics are defined in Table 1.

Table 1:  Flash Duration

Type

Intensity

Intensity Step

Flash rateFootnote (1)

Flash DurationFootnote (2)

CL-856

high

day & twilight

40fpm

less than 200ms

night

40fpm

between 100 and 250ms

CL-857

high

day & twilight

60fpm

less than 200ms

night

60fpm

between 100 and 250ms

CL-864

medium

night

20-40fpm

1/2 to 2/3 of flash period if incandescent lighting Footnote (note 3), and between 100 and 2/3 of flash cycle if other light source.

CL-865

medium

day & twilight

40fpm

less than 200ms

night

40fpm

between 100 and 2/3 of the flash cycle

CL-866

medium

day & twilight

60fpm

less than 200ms

night

60fpm

between 100 and 2/3 of the flash cycle

CL-885

medium

night

60fpm

1/2 to 2/3 of flash period if incandescent lighting (note 3), and between 100 and 2/3 of the flash cycle if other light source.

fpm = flashes per minute
ms = milliseconds
(effective 2016/03/01)

3.4.3 System Flashing Requirements

3.4.3.1 Simultaneous Flashing Systems

All obstruction lights in systems composed of either CL-864 light units or CL-856 and/or CL-865 light units flash within 1/60 of a second of each other.

3.4.3.2 Sequenced Flashing Systems

(a) Catenary support structure systems composed of CL-857, CL-866, or CL-885 light units have a sequenced flashing characteristic.

(b) This system consists of three lighting levels on or near each supporting structure. One light level is near the top, one at the bottom or lowest point of the catenary, and one midway between the top and bottom.

(c) The flash sequence is middle, top, and bottom.

(d) The interval between top and bottom flashes is about twice the interval between middle and top flashes.

(e) The interval between the end of one sequence and the beginning of the next is about 10 times the interval between middle and top flashes.

(f) The time for the completion of one cycle is one second (±5 percent).

3.4.4 Intensity Step Changing

3.4.4.1 White Obstruction Lights

Refer Standard 621 for photocell settings for day, twilight and night operation.

3.4.4.2 Red Obstruction Lights

Refer Standard 621 for photocell settings for night operation.

4.0 EQUIPMENT QUALIFICATION REQUIREMENTS

4.1 Qualification Tests - General

(a) Qualification tests are conducted on the light unit in the following order:

  1. (i) Initial photometric test, per section 4.2;
  2. (ii) Environmental tests, per sections 4.3, 4.4, 4.5, 4.6, 4.7, 4.8 and 4.9 (in any order);
  3. (iii) 1000 hours of continuous operation, per section 4.10;
  4. (iv) System Operational Test, per section 4.10; and
  5. (v) Sampling Photometric Test, per section 4.2.

(b) Sample photometric and system operational tests are conducted after completion of all environmental tests.

(c) The same unit(s) is used throughout the tests.

(d) The tests may be run on the control unit, power supply, and a single light unit, with a simulated load replacing the other light units.

(e) Equipment is tested as a complete system.

4.2 Photometric Test

(a) A full photometric test as described in this section is performed before all environmental tests.

NOTE:  To verify proper colour correction, photometric testing conducted on alternative light source fixtures is done with a detector having an up to date calibration including spectral response data.

(b) A sampling photometric retest is conducted after the unit has been operated continuously for 1000 hours with normal (12 hour) day/night cycling.

(c) This sampling consists of measuring the vertical beam pattern for compliance with photometric requirements at a minimum of two of the previously tested horizontal radials.

(d) Light units are energized by the system power supply and control unit, and are tested for compliance with photometric requirements.

(e) Incandescent lamps are tested at ?3 percent of their nominal voltage.

(f) Red light intensity may be measured in white light and then calculated if the glassware manufacturer certifies the chromaticity and transmissivity values of the red filter material for the particular source.

(g) If more than one lamp type is to be used, the qualification testing is completed for each lamp type.

(h) For a discharge type flashing system, if the power supply and optical head are separate components, the manufacturer demonstrates that the required photometrics are produced with the units separated by maximum and minimum recommended distances and connected by cable recommended by the manufacturer.

(i) Photometric test results are in the forms of:

  1. (i) points over range of specified angles; and

  2. (ii) Horizontal beam pattern: Polar plot (horizontal angle versus candela) with a minimum 30 degree spacing of test points.

4.3 High Temperature Test

(a) The high temperature test is conducted per MIL-STD-810F, Method 501.4, Procedure II.

(b) The equipment is subjected to a constant temperature of +55 degrees Celsius for 4 hours after equipment temperature stabilization and be operated throughout the test.

NOTE:  For steady state temperature testing, consider thermal stabilization to be achieved when the temperatures of critical internal operating components are relatively constant. (Because of test item duty cycling or the operating characteristics, a constant temperature may never be achieved.)

(c) During the test, the manufacturer demonstrates that the equipment maintains the specified flash rate and (for discharge type flashing light) the proper amount of energy is being delivered to the flashtube as the input voltage is varied by ±10 percent from nominal.

(d) A visual examination is conducted after the equipment is removed from the chamber. Failure of the equipment to operate as specified is cause for rejection.

4.4 Low Temperature Test

(a) The low temperature test is conducted per MIL-STD-810F, Method 502.4, Procedure II.

(b) The equipment is placed in a chamber that maintains a temperature of -55 degrees Celsius for shipping/storage requirements and -40 degrees Celsius for equipment operational requirements.

(c) Equipment operation is demonstrated at the beginning of the test.

(d) The equipment storage and shipping low temperature requirement is -55 degrees Celsius.

(e) The equipment is stabilized and cold soaked at the storage/shipping temperature for one hour.

(f) The test chamber is then ramped to the -40 degrees Celsius equipment operating temperature at no more than 14.4 degrees Celsius per minute to prevent thermal shock to the equipment.

(g) The equipment, with input power off, is then exposed to a 24-hour soaking period at ­40 degrees Celsius after which the equipment is turned on for one hour, and operates normally.

(h) The unit achieves specified flash rate and intensity within 1 minute after being energized.

(i) For rotating type beacons having HID (high intensity discharge) lamps and intended for continuous operation once installed, the unit achieves specified flash rate and the arc struck as to commence an output within 1 minute after being energized and achieves specified intensity within 5 minutes of being turned on.

(j) During the one hour of operation, the manufacturer demonstrates that the equipment maintains the specified flash rate and, for capacitor discharge type flashing lights (strobe lighting), the proper amount of energy is being delivered to the flashtube as the input voltage is varied by ±10 percent from nominal.

(k) At the conclusion of the test, a visual inspection is conducted.

(l) Failure of the equipment to operate as specified is cause for rejection.

4.5 Rain Test

(a) The wind-blown rain test is conducted per MIL-STD-810F, Method 506.4, Procedure I, paragraph 4.4.2.

(b) The rain is at a rate of 132mm/hour with an exposure time of 30 minutes per side.

(c) The equipment is operated throughout the test. Failure of the equipment to operate as specified is cause for rejection.

4.6 Wind Test

Evidence is provided, either by testing or by calculation of mechanical force, to demonstrate that installed light units meet the wind requirement in paragraph 3.2(c).

4.7 Humidity Test

(a) The test is per MIL-STD-810F, Method 507.4, paragraph 4.5.2. The equipment is subjected to two complete cycles per Table 507.4-1, except the maximum chamber temperature is +55 degrees Celsius.

(b) Failure of the equipment to operate as specified is cause for rejection.

4.8 Salt Fog Test

(a) The salt fog test is conducted per MIL-STD-810F, Method 509.4, paragraph 4.5.2.

(b) Failure of the equipment to operate as specified is cause for rejection.

(c) If corrosion is present, the third party certification body determines if it has impacted equipment structural integrity or functionality.

4.9 Sunshine Test

NOTE:  The manufacturer may submit a certificate of compliance (for consideration by the third party certification body) from the manufacturer attesting to UV resistance (per MIL-STD-810F) in lieu of the testing requirements below.

(a) The equipment is in its normal operational configuration for this test.

(b) A sunshine test is conducted per MIL-STD-810F, Method 505.4, paragraph 4.4.3, Procedure II for all obstruction lighting equipment with nonmetallic exterior parts or plastic/thermoplastic light covers.

(c) The equipment is subjected to a minimum of 56 cycles.

(d) An operational test of the equipment is performed after 56 cycles.

(e) Any evidence of deterioration of plastic parts: chalking, bleaching, cracking, hazing, or colour changes (yellowing) to the thermoplastic lenses of the test unit is cause for rejection.

(f) For plastic/thermoplastic optical lenses or covers, the photometric performance is measured after this test.

4.10 System Operational Test

(a) A system operational test is performed after the unit has been operated continuously without failure for 1000 hours with normal (12 hour) day/night cycling.

(b) System components are connected with the necessary wiring to electrically simulate an actual installation in which the top and bottom light units on a structure are separated by 600 m for a system composed of CL-856 and/or CL-865 and 150 m for a system composed of CL-857 or CL 866, and the controller separated an additional 760 m.

(c) Simulated interconnecting cables with equivalent impedance may be used in lieu of full cable lengths.

(d) The system is energized and operated to demonstrate compliance with all specification operating requirements such as flash rate, flash sequence, photoelectric switching of intensity steps, operation of interlocked devices, and satisfactory operation under input voltage variations.

(e) If the power supply and optical head are separate components, it is demonstrated that with the maximum and minimum nameplate rated separation between components, proper energy is delivered to the light unit to produce the specified photometrics.

(f) It is demonstrated that CL-810 and CL-864 lights produce the specified photometric requirement when energized over conductors (actual or simulated) representing the maximum and minimum nameplate rated cable length at the minimum input voltage.

(g) The monitoring capability of flashing light system controller to 3.3.5.1.1 and 3.3.5.2.2 is verified.
(effective 2016/03/01)